Evaluation of Drug Susceptibility in Nontuberculous Mycobacteria Using the SLOMYCO and RAPMYCO Sensititre Plates
Authors:
- 1 October 2021
- journal article
- research article
- Published by Medknow in The International Journal of Mycobacteriology
- Vol. 10 (4) , 379-387
Abstract
Background: Non-tuberculous Mycobacteria (NTM) cause different forms of diseases. According to recent guideline by ATS/ERS/ESCMID/IDSA, drug susceptibility test (DST) is an important requirement to choose adequate treatment. The minimum inhibitory concentration (MIC) test is the recommended method. Sensititre SLOMYCO and RAPMYCO commercial panels were developed to perform mycobacteria DST easier. However, there are only two comparative studies between SLOMYCO and the MIC method and none for the RAPMYCO panel. The present study aimed to evaluate the Sensititre SLOMYCO and RAPMYCO plates in determining drug susceptibility compared to the gold standard method (MIC). Methods: The tests were carried out with clinical isolates received in the diagnostic routine of the Tuberculosis Laboratory at Institute Adolfo Lutz from the most frequent species in the state of São Paulo, Brazil. Reference strains were tested for repeatability and reproducibility analyses. MIC and Sensititre plates readings were compared with and without resazurin stain. Agreement between results was defined as MIC within the same dilution or dilution variation resulting the same category in both tests. Results were classified by categorical errors. Results: The RAPMYCO panel had 100% agreement for the drugs amikacin, doxycycline, ciprofloxacin and trimethoprim/sulfamethoxazole, 83.3% for clarithromycin and moxifloxacin and 60% for cefoxitin. The SLOMYCO panel had 80% agreement for amikacin and moxifloxacin and 60% for clarithromycin, rifabutin, rifampicin and ciprofloxacin. The repeatability and reproducibility with RAPMYCO and SLOMYCO plates showed a high level of agreement for the drugs tested, being higher with the use of resazurin. However, an evaluation on routine condition is needed. Conclusions: The present study found that the fewer steps in the tests with Sensititre plates and reading with resazurin allow its use with greater safety and efficiency in the laboratory routine. The results presented here will facilitate the execution of a validation for complete incorporation of Sensititre plates into a diagnostic routine.Keywords
This publication has 22 references indexed in Scilit:
- Diagnosis of Nontuberculous Mycobacterial InfectionsSeminars in Respiratory and Critical Care Medicine, 2013
- Resistance mechanisms and drug susceptibility testing of nontuberculous mycobacteriaDrug Resistance Updates, 2012
- Evaluation of Mycobacterium avium Complex Clarithromycin Susceptibility Testing Using SLOMYCO Sensititre Panels and JustOne StripsJournal of Clinical Microbiology, 2010
- Isolamento de micobactérias não-tuberculosas em São José do Rio Preto entre 1996 e 2005Jornal Brasileiro de Pneumologia, 2008
- Estudo descritivo da freqüência de micobactérias não tuberculosas na Baixada Santista (SP)Jornal Brasileiro de Pneumologia, 2008
- Reliable identification of mycobacterial species by PCR-restriction enzyme analysis (PRA)-hsp65 in a reference laboratory and elaboration of a sequence-based extended algorithm of PRA-hsp65patternsBMC Microbiology, 2008
- An Official ATS/IDSA Statement: Diagnosis, Treatment, and Prevention of Nontuberculous Mycobacterial DiseasesAmerican Journal of Respiratory and Critical Care Medicine, 2007
- Multisite Reproducibility of Results Obtained by Two Broth Dilution Methods for Susceptibility Testing of Mycobacterium avium ComplexJournal of Clinical Microbiology, 2003
- Epidemiology of human pulmonary infection with mycobacteria nontuberculousClinics in Chest Medicine, 2002
- Resazurin Microtiter Assay Plate: Simple and Inexpensive Method for Detection of Drug Resistance in Mycobacterium tuberculosisAntimicrobial Agents and Chemotherapy, 2002