The Maxi Stabil 3: validation of an aneroid device according to a modified British Hypertension Society protocol
Authors:
- Clare R JonesCJClare R Jones
- Alexandra C CucksonACAlexandra C Cuckson
- Andrew H. ShennanASAndrew H. Shennan
- 1 April 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 8 (2) , 83-89
Abstract
Measuring blood pressure with mercury-independent alternatives is rapidly gaining attention. Mercury will be phased out of clinical use as a result of environmental, health and safety concerns and it is of vital importance that any alternative to mercury has to be of a recognized standard. We assessed the accuracy of the Maxi Stabil 3 aneroid device in an adult population according to a modified British Hypertension Society protocol (with the low systolic category changed from less than 90 mmHg to less than 100 mmHg). Eighty-five subjects were recruited from among staff and patients at Guy's and St Thomas' Hospitals, London, UK. The aneroid device was connected in parallel to two mercury sphygmomanometers. Nine sequential same-arm measurements were taken from each subject by two trained observers, alternating between mercury sphygmomanometry and the aneroid device. Simultaneous mercury readings were also recorded for additional analysis. The device achieved an A grade for both systolic and diastolic pressures and fulfilled the requirements of the Association for the Advancement of Medical Instrumentation. The mean and standard deviation for systolic and diastolic pressures respectively were -0.6 (4.6) mmHg and -1.3 (3.5) mmHg in sequential analysis, and -1.3 (2.2) mmHg and -1.9 (2.7) mmHg in simultaneous analysis. The Maxi Stabil aneroid device can be recommended for use in an adult population.Keywords
This publication has 14 references indexed in Scilit:
- Practice audits: reliability of sphygmomanometers and blood pressure recording biasJournal of Human Hypertension, 2002
- Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adultsBlood Pressure Monitoring, 2002
- The case for a hybrid sphygmomanometerBlood Pressure Monitoring, 2001
- Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experienceBlood Pressure Monitoring, 2001
- Are Aneroid Sphygmomanometers Accurate in Hospital and Clinic Settings?Archives of internal medicine (1960), 2001
- How accurate are sphygmomanometers?Journal of Human Hypertension, 1998
- Aneroid sphygmomanometers. An assessment of accuracy at a university hospital and clinicsArchives of internal medicine (1960), 1991
- Accuracy of prehospital sphygmomanometersThe Journal of Emergency Medicine, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Sphygmomanometers in hospital and family practice: problems and recommendations.BMJ, 1982