Relationship between retinal distance and object field angles for finite schematic eyes
- 19 May 2016
- journal article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 36 (4) , 404-410
Abstract
Aim: Retinal anatomical studies have used the Drasdo & Fowler three‐refracting surface schematic eye to convert between retinal distances and object field angles. We compared its performance at this task with those of more sophisticated four‐refracting surface schematic eyes. Method: Raytracing was performed for Drasdo & Fowler, Lotmar, Navarro, Liou & Brennan, Kooijman and Atchison schematic eyes, and some of their variants. Results: The Drasdo & Fowler eye gives a greater rate of change of object field angle with retinal distance at the retinal centre of about 5% than the other schematic eyes. This rate of change also increases much more quickly into the peripheral retina for the Drasdo & Fowler eye than for the other eyes. The reason for these differences is only that the Drasdo & Fowler eye is shorter than the other eyes. The relationship between retinal distance and visual field angle appears robust to changes in retinal radius of curvature when the retina is spherical. The retinal asphericity of Kooijman and Atchison eyes appears to play a role beyond 14 mm (~50°). Conclusion: Changing the length of the Drasdo & Fowler eye, to match those of the four‐refracting surface schematic eyes, gives similar relationships between retinal distance and object field angle up to a retinal distance of approximately 14 mm (~50°). The relationship will change with refractive error as this is related to axial length and to retinal shape, and this should be taken into consideration for accurate conversions. For distances and angles beyond 14 mm and ~50°, retinal shape should be taken into account.Keywords
Funding Information
- Shandong Provincial Education Association for International Exchanges
- ARC Discovery (DP140101480)
This publication has 15 references indexed in Scilit:
- High-Fidelity Reproduction of Spatiotemporal Visual Signals for Retinal ProsthesisNeuron, 2014
- Variations in image optical quality of the eye and the sampling limit of resolution of the cone mosaic with axial length in young adultsJournal of Cataract & Refractive Surgery, 2012
- Off-axis aberrations of a wide-angle schematic eye modelJournal of the Optical Society of America A, 1999
- Anatomically accurate, finite model eye for optical modelingJournal of the Optical Society of America A, 1997
- Packing geometry of human cone photoreceptors: Variation with eccentricity and evidence for local anisotropyVisual Neuroscience, 1992
- Distribution and morphology of human cone photoreceptors stained with anti‐blue opsinJournal of Comparative Neurology, 1991
- Topography of ganglion cells in human retinaJournal of Comparative Neurology, 1990
- Human photoreceptor topographyJournal of Comparative Neurology, 1990
- Light distribution on the retina of a wide-angle theoretical eyeJournal of the Optical Society of America, 1983
- Theoretical Eye Model with Aspherics*Journal of the Optical Society of America, 1971