Effects of Vibration Stress and Temperature on the Characteristics of Piezoelectric Ceramics under High Vibration Amplitude Levels Measured by Electrical Transient Responses
Authors:
- Mikio UmedaMUMikio Umeda
- Kentaro NakamuraKNKentaro Nakamura
- Sadayuki UehaSUSadayuki Ueha
- 1 September 1999
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 38 (9S) , 5581-5585
Abstract
This paper presents a characteristic evaluation of piezoelectric ceramics at high vibration amplitude levels of resonance, based on the electrical transient response technique. Low-Q and high-Q materials are measured, and the effect of vibration stress is obtained without affecting temperature. It is revealed that for low-Q materials an increase of loss is caused mainly by the vibration stress, while for high-Q materials, it is caused by both the vibration stress and the temperature increase. The results show that in some high-Q materials, it is meaningless to evaluate the piezoelectric materials at low vibration level, since the characteristics change variously at high vibration levels. The force factor is changed mainly by the temperature, although its behavior is different, depending on material composition.Keywords
This publication has 4 references indexed in Scilit:
- Effects of a Series Capacitor on the Energy Consumption in Piezoelectric Transducers at High Vibration Amplitude LevelJapanese Journal of Applied Physics, 1999
- The Measurement of High-Power Characteristics for a Piezoelectric Transducer Based on the Electrical Transient ResponseJapanese Journal of Applied Physics, 1998
- Nonlinear Piezoelectric Effect in Ferroelectric CeramicsJapanese Journal of Applied Physics, 1998
- High Power Transformer Employing Piezoelectric CeramicsJapanese Journal of Applied Physics, 1996