Advanced imaging improves detection of baffle leaks and stenoses after atrial switch compared with transthoracic echocardiography
- 17 April 2021
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 37 (9) , 2767-2772
Abstract
Current guidelines for adults with atrial switch repair recommend baseline cardiovascular magnetic resonance (CMR) for assessment of ventricular size and function, systemic and venous baffle obstruction and leaks, and valvular function. It also recommends transthoracic echocardiography (TTE) for outpatient follow up. Many such patients with implanted cardiac devices may need cardiac computed tomography (CCT) when CMR is not feasible. This study reviews and compares CMR, transesophageal echocardiography (TEE), CCT, cardiac catheterization with angiography and TTE in detection of baffle problems in patients after atrial switch operation. The medical records of patients who had at least one imaging study performed after atrial switch operation at our center from 2010 to 2020 were retrospectively reviewed. Results are reported as descriptive statistics for demographics and imaging findings. The principal outcome measure was detection of baffle leak and/or baffle stenosis. Fifty-seven patients had at least one cardiac imaging study after atrial switch operation (36 Senning and 21 Mustard operations) during the study period. Nearly 33% (19/57) had baffle complications of stenosis and/or baffle leaks identified. All 57 patients had TTE performed but baffle problems were noted by TTE in only 8 (14%) patients (7 baffle stenosis and 1 baffle leak). Of the 49 patients without known baffle problems by TTE, 24 had advanced imaging (TEE/CCT/CMR/angiography). Advanced imaging identified baffle problems in nearly half (11/24, 46%) of them (7 baffle leaks and 4 baffle stenosis). Baffle problems were present in (8/23) patients with transvenous cardiac devices. Baffle complications are common after atrial switch operations and in our study occur in 1/3rd of the patients. However, TTE is not sensitive enough to recognize these complications. Advanced imaging for detection of baffle complications should be considered in all patients after atrial switch operationKeywords
This publication has 15 references indexed in Scilit:
- Mustard baffle obstruction and leak – How successful are percutaneous interventions in adults?Progress in Pediatric Cardiology, 2015
- Accuracy of Imaging Modalities in Detection of Baffle Leaks in Patients Following Atrial Switch OperationEchocardiography, 2015
- Increasing Mortality Burden among Adults with Complex Congenital Heart DiseaseCongenital Heart Disease, 2014
- Stenosis of the superior limb of the systemic venous baffle following a Mustard procedure: An under-recognized problemInternational Journal of Cardiology, 2012
- Comparison between Transthoracic Echocardiography and Cardiac Magnetic Resonance Imaging in Patients Status Post Atrial Switch ProcedureCongenital Heart Disease, 2011
- Atrial Baffle Problems Following the Mustard Operation in Children and Young Adults with Dextro-Transposition of the Great Arteries: The Need for Improved Clinical Detection in the Current EraCongenital Heart Disease, 2011
- Ventricular arrhythmias and sudden death in adults after a Mustard operation for transposition of the great arteriesEuropean Heart Journal, 2009
- A simplified approach for assessment of intracardiac baffles and extracardiac conduits in congenital heart surgery with two- and three-dimensional magnetic resonance imagingAmerican Heart Journal, 2001
- Results of the double switch operation in the current eraThe Annals of Thoracic Surgery, 2000
- Results of the Mustard operation for dextro-transposition of the great arteriesThe Journal of Thoracic and Cardiovascular Surgery, 1981