Early fitting in cochlear implant surgery: preliminary results
Authors:
Open Access
- 7 July 2023
- journal article
- research article
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 281 (1) , 61-66
Abstract
Purpose: Cochlear implants are usually activated 3–5 weeks after surgery; to date, no universal protocol exists regarding switch on and fitting of these devices. The aim of the study was to assess safety and functional results of activation and fitting of cochlear implant within 24 h following surgery. Methods: In this retrospective case–control study, 15 adult patients who underwent cochlear implant surgery, for a total of 20 cochlear implant procedures were analyzed. In particular, clinical safety and feasibility were investigated by examinating patients at activation and at each follow-up. Values of electrodes’ impedance and most comfortable loudness (MCL) were analyzed from the time of surgery to 12 months after activation. Free-field pure tone average (PTA) was also recorded. Results: No major or minor complications were reported and all patients could perform the early fitting. Activation modality influenced impedance values only in the short term but the differences were not statistically significant (p > 0.05). Mean MCL values in the early fitting group were lower than MCL of the late fitting in all follow-up sessions, and the difference was statistically significant (p < 0.05). The mean PTA was lower in the early fitting group but the difference was not statistically significant (p < 0.05). Conclusions: Early fitting of cochlear implants is safe, allows for an early rehabilitation and can have possible beneficial effects on stimulation levels and dynamic range.Keywords
Funding Information
- Università degli Studi di Parma
This publication has 22 references indexed in Scilit:
- Feasibility of one-day activation in cochlear implant recipientsInternational Journal of Audiology, 2015
- Cochlear Implant Device Activation and ProgrammingOtology & Neurotology, 2014
- Impedance and Electrically Evoked Compound Action Potential (ECAP) Drop within 24 Hours after Cochlear ImplantationPLOS ONE, 2013
- Minimal access and standard cochlear implantation: A comparative studyInternational Journal of Pediatric Otorhinolaryngology, 2012
- Comparison of Electrically Evoked Compound Action Potential Thresholds and Loudness Estimates for the Stimuli Used to Program the Advanced Bionics Cochlear ImplantJournal of the American Academy of Audiology, 2010
- Complication rate of minimally invasive cochlear implantationOtolaryngology–Head and Neck Surgery, 2006
- Measurement and Analysis of Access Resistance and Polarization Impedance in Cochlear Implant RecipientsOtology & Neurotology, 2005
- A study of intra-cochlear electrodes and tissue interface by electrochemical impedance methods in vivoBiomaterials, 2004
- Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implantInternational Journal of Pediatric Otorhinolaryngology, 2003
- Intracochlear Factors Contributing to Psychophysical Percepts Following Cochlear ImplantationActa Oto-Laryngologica, 1998