A New Tailored Approach to Calculate the Optimal Number of Outdoor Air Changes in School Building HVAC Systems in the Post-COVID-19 Era
Open Access
Abstract
Air conditioning systems can play a positive or negative role in the spread of COVID-19 infection. The importance of sufficient outdoor air changes in buildings was highlighted by the World Health Organization, therefore these should be guaranteed by mechanical ventilation systems or adequate air conditioning systems. The proposed case study concerns the optimal number of outdoor air changes to limit COVID-19 contagion for a school building in Central Italy. The Wells–Riley model is used to assess the risk of airborne infection, while energy consumption is calculated by a dynamic energy simulation software. The scope of the paper offers an innovative method to define the optimal ventilation strategy for the building’s HVAC system design to reduce the risk of infection with limited increases in energy consumption and greenhouse gas emissions. Results show that the desirable approach is the one in which the same low value of contagion risk is set in all rooms. This new approach results in significant energy savings, compared to the most common ones (setting the same high outdoor air rates for all rooms) to counteract the risk of infection. Finally, the zero-emission building target is verified by introducing a suitable photovoltaic system to offset pollutant emissions.Keywords
Funding Information
- Sustainable Energy Systems for High Efficiency Buildings (CUP E65F21003190003, CUP E69J2200110000)
- Italian Ministry of University and Research (MUR) (CUP E65F21003190003, CUP E69J2200110000)
- Programma Operativo Nazionale Ricerca e Innovazione 2014–2020—Azione IV.5 Dottorati su tematiche Green (CUP E65F21003190003, CUP E69J2200110000)
This publication has 97 references indexed in Scilit:
- Performance evaluation of building integrated photovoltaic system arrays (SP, TT, QT, and TCT) to improve maximum power with low mismatch loss under partial shadingMicrosystem Technologies, 2023
- Indoor air quality and its health effects in offices and school buildings in the Yangtze River DeltaAir Quality, Atmosphere & Health, 2023
- Design, development and performance analysis of FSPV system for powering sustainable energy based mini micro-gridMicrosystem Technologies, 2023
- Global sensitivity analysis and optimal design of heat recovery ventilation for zero emission buildingsApplied Energy, 2022
- Effects of operating room layout and ventilation system on ultrafine particle transport and depositionAtmospheric Environment, 2022
- A stochastic operational planning model for a zero emission building with emission compensationApplied Energy, 2021
- COVID-19 Impact on Operation and Energy Consumption of Heating, Ventilation and Air-Conditioning (HVAC) SystemsAdvances in Applied Energy, 2021
- A fresh (air) look at ventilation for COVID-19: Estimating the global energy savings potential of coupling natural ventilation with novel radiant cooling strategiesApplied Energy, 2021
- Dilution-based evaluation of airborne infection risk - Thorough expansion of Wells-Riley modelBuilding and Environment, 2021
- Room ventilation and the risk of airborne infection transmission in 3 health care settings within a large teaching hospitalAmerican Journal of Infection Control, 2011