Factors Associated With Failure of High-Flow Nasal Cannula
Authors:
- 24 March 2020
- journal article
- research article
- Published by SAGE Publications in Respiratory Care
- Vol. 65 (9) , 1276-1284
Abstract
BACKGROUND: The use of high-flow nasal cannula (HFNC) is rapidly increasing without clear indications, creating the potential for overuse or misuse and the accompanying risk of adverse events. The purpose of this study was to determine the factors associated with HFNC failure by examining the current clinical practice of HFNC. METHODS: From July 1, 2017, to June 30, 2018, in 5 university-affiliated hospitals in the Republic of Korea, a total of 1,161 admitted adult subjects who had HFNC administered were retrospectively enrolled and their medical records were reviewed. RESULTS: Pulmonary diseases including pneumonia ( n = 757, 65.2%) were the most common reason for use of HFNC. Subjects with do-not-resuscitate (DNR) or do-not-intubate (DNI) orders comprised 33.8% of the study population ( n = 392); 563 subjects (48.5%) were escalated directly to HFNC from low-flow devices without applying reservoir or other high-flow devices. In the non-DNR/DNI subjects, arterial blood gas was not monitored in 15.2% and 14.8% of subjects before and after HFNC application, respectively, and it was not monitored in 28.0% just before HFNC weaning. The HFNC failure rate was 27.0% in non-DNR/DNI subjects, and the HFNC failure was significantly associated with the decision by residents to apply HFNC (odds ratio [OR] 2.03, 95% CI 1.29–3.18, P = .002), high breathing frequency (OR 1.07, 95% CI 1.04–1.10, P < .001) ≤ 6 h before HFNC application, low S aO 2 (OR 0.92, 95% CI 0.89–0.95, P < .001) ≤ 6 h before HFNC application, low S pO 2 (OR 0.95, 95% CI 0.93–0.98, P < .001) ≤ 6 h before HFNC application, and the ratio of S pO 2 / F IO 2 to breathing frequency (ROX index) ≤ 6 h after HFNC application (OR 0.88, 95% CI 0.84–0.92, P < .001). CONCLUSIONS: HFNC was practiced without applying reservoir or other high-flow devices before application and without appropriate arterial blood gas monitoring during HFNC therapy. HFNC failure was significantly associated with the decision by the resident to use HFNC, breathing frequency, S aO 2 , and S pO 2 ≤ 6 h before HFNC application, and with the ROX index ≤ 6 h after HFNC application.Keywords
This publication has 40 references indexed in Scilit:
- Failure of high-flow nasal cannula therapy may delay intubation and increase mortalityIntensive Care Medicine, 2015
- Sequential Application of Oxygen Therapy Via High-Flow Nasal Cannula and Noninvasive Ventilation in Acute Respiratory Failure: An Observational Pilot StudyRespiratory Care, 2014
- Nasal High-Flow versus Venturi Mask Oxygen Therapy after Extubation. Effects on Oxygenation, Comfort, and Clinical OutcomeAmerican Journal of Respiratory and Critical Care Medicine, 2014
- Patients with New York Heart Association class III heart failure may benefit with high flow nasal cannula supportive therapyJournal of Critical Care, 2013
- High-Flow Nasal Cannula Therapy in Do-Not-Intubate Patients With Hypoxemic Respiratory DistressRespiratory Care, 2013
- Noninvasive CPAP With Face Mask: Comparison Among New Air-Entrainment Masks and the Boussignac ValveRespiratory Care, 2013
- The Berlin definition of ARDS: an expanded rationale, justification, and supplementary materialIntensive Care Medicine, 2012
- Impact of high-flow nasal cannula oxygen therapy on intensive care unit patients with acute respiratory failure: A prospective observational studyJournal of Critical Care, 2012
- Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patientsBritish Journal of Anaesthesia, 2011
- Humidified High-Flow Nasal Oxygen Utilization in Patients with Cancer at Memorial Sloan-Kettering Cancer CenterJournal of Palliative Medicine, 2011