Design of a high-resolution extreme-ultraviolet imaging spectrometer with aberration-corrected concave gratings
Authors:
- 1 October 1998
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 37 (28) , 6803-6810
Abstract
A high-resolution extreme-ultraviolet imaging spectrometer is designed for the Japanese solar mission Solar-B. A spherical varied-line-space (SVLS) grating and a toroidal uniform-line-space (TULS) grating are chosen as candidates for use in the spectrometer to yield high spectral and spatial resolution within the spectral range 25–29 nm. The spectral image-focusing properties and the mechanical tolerances for fabrication and alignment are compared for the two types of grating. The SVLS design is found to be superior to the TULS design for off-plane spectral images and in ease of fabrication and optical alignment.Keywords
This publication has 17 references indexed in Scilit:
- Ruling engine using a piezoelectric device for large and high-groove density gratingsApplied Optics, 1992
- Soft x-ray monochromator with a varied-space plane grating for synchrotron radiation: design and evaluationApplied Optics, 1989
- Mechanically ruled diffraction gratings for synchrotron radiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1986
- Extreme Ultraviolet Explorer spectrometerApplied Optics, 1985
- Development of a flat-field grazing-incidence XUV spectrometer and its application in picosecond XUV spectroscopyApplied Optics, 1984
- Use of aberration-corrected concave gratings in optical demultiplexersApplied Optics, 1983
- Mechanically ruled aberration-corrected concave gratings for a flat-field grazing-incidence spectrographApplied Optics, 1983
- Mechanically ruled aberration-corrected concave gratingsApplied Optics, 1980
- Mechanically ruled aberration-corrected concave grating for high resolution Seya-Namioka monochromator.Journal of the Spectroscopical Society of Japan, 1980
- Mechanically Ruled Stigmatic Concave GratingsJapanese Journal of Applied Physics, 1975