Can C.T. detect labyrinthine fistulae pre-operatively?
Authors:
- 1 January 1988
- journal article
- research article
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 106 (1-2) , 40-45
Abstract
The aim of the study was to undertake a controlled prospective evaluation of high resolution computerized tomography in the pre-operative diagnosis of labyrinthine fistulae. Fifty consecutive patients with chronic suppurative otitis media were scanned prior to surgery, using a Siemens DRI scanner. The radiological predictions were then compared with the surgical findings. Five patients had labyrinthine erosions and these were predicted in 4 out of the 5 (80%). The one erosion that escaped radiological detection was less than 2 mm in length. The study shows that high resolution computerized tomography is a highly accurate method for demonstrating pre-operatively all but the smallest fistulae.Keywords
This publication has 5 references indexed in Scilit:
- The predictive value of high resolution computerized tomography in chronic suppurative ear diseaseClinical Otolaryngology, 1987
- Surgical management of labyrinthine fistula with cholesteatomaThe Journal of Laryngology & Otology, 1986
- Labyrinthine Fistula in Chronic MastoiditisAnnals of Otology, Rhinology & Laryngology, 1984
- Computed tomography in suppurative ear disease: A correlation of surgical and radiographic findingsThe Laryngoscope, 1984
- Cholesteatoma surgery: Management of the labyrinthine fistula—A report of 97 casesThe Laryngoscope, 1979