An Alternative Approach to the Simulation of Wind Effects on the Thermal Performance of Buildings

Authors:

Abstract
The new method described in this paper incorporates the wind effect surrounding the buildings into the external air temperature by the use of an equivalent temperature (called here Tnatural) which produces the same rate of convection heat loss like that with the wind effects included. The internal air temperature of the building can be then calculated using this new external air temperature Tnatural.. Simulations using this approach were compared with the real data from four existing housing test modules incorporating a range of walling systems, resulted in an accurate, representative analysis as well as a significantly reducing simulation time.

This publication has 11 references indexed in Scilit: