Evaluation of implantable collamer lens sizing developed by reviewing the horizontal compression-vault coefficient
- 1 May 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (5) , 525-530
Abstract
Purpose: To evaluate the implantable collamer lens (ICL) sizing method using the partial regression coefficient of the implanted ICL size to review the conventional horizontal compression coefficient and match the results of clinical observation. Setting: Nagoya Eye Clinic, Nagoya, Japan. Design: Interventional case series. Methods: Patients who underwent ICL V4c implantation to correct myopia and myopic astigmatism were enrolled. The stepwise multiple regression analysis used achieved vault as a dependent variable and preoperative biometric parameters as explanatory variables. The partial regression coefficient of the implanted ICL size was obtained to develop the optimal ICL-sizing formula, the NK-formula version 3 (NK-formula V3). Eighty-five eyes of 45 patients were implanted with an ICL size recommended by the NK-formula V3. At 3 months postoperatively, the achieved vault was measured using AS-OCT to validate the NK-formula V3. Results: The study enrolled 174 patients (174 eyes). The partial regression coefficient of the implanted ICL size adopted as the compression-vault coefficient in the multiple regression equation predicting the vault was 0.729. To validate the NK-formula V3, 77 (90.6%), seven (8.2%), and one (1.2%) eye were in the moderate, low, and high vault categories, respectively. The mean difference between the achieved and predicted vault was 0.064±0.190 (range: -0.264–0.742) mm for the NK-formula V3 and 0.176±0.217 (range: -0.254–0.907) mm for the NK-formula V2. Conclusions: As in vivo coefficient measurement experiments are not possible, the partial regression coefficient is the best option for developing a formula to predict the optimal ICL size.Keywords
This publication has 15 references indexed in Scilit:
- Buffering zone of implantable Collamer lens sizing in V4cBMC Ophthalmology, 2017
- Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lensClinical Ophthalmology, 2016
- Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomographyJournal of Cataract & Refractive Surgery, 2015
- Comparison of Postoperative Vault Height Predictability Using White-to-White or Sulcus Diameter–based Sizing for the Visian Implantable Collamer LensJournal of Refractive Surgery, 2013
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Optimization of an Implantable Collamer Lens Sizing Method Using High-Frequency Ultrasound BiomicroscopyAmerican Journal of Ophthalmology, 2012
- Correlation between Preoperative Biometry and Posterior Chamber Phakic Visian Implantable Collamer Lens VaultingOphthalmology, 2012
- Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopyJournal of Cataract & Refractive Surgery, 2011
- United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopiaOphthalmology, 2004
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986