Accuracy of tumor segmentation from multi-parametric prostate MRI and 18F-choline PET/CT for focal prostate cancer therapy applications
Authors:
- Morand PiertMPMorand Piert
- Prasad R. ShankarPSPrasad R. Shankar
- Jeffrey MontgomeryJMJeffrey Montgomery
- Lakshmi Priya KunjuLKLakshmi Priya Kunju
- Virginia RogersVRVirginia Rogers
- Javed SiddiquiJSJaved Siddiqui
- Thekkelnaycke RajendiranTRThekkelnaycke Rajendiran
- Jason HearnJHJason Hearn
- Arvin GeorgeAGArvin George
- Xia ShaoXSXia Shao
- Matthew S. DavenportMDMatthew S. Davenport
Open Access
- 27 March 2018
- journal article
- research article
- Published by Springer Nature in EJNMMI Research
- Vol. 8 (1) , 1-14
Abstract
The study aims to assess the accuracy of multi-parametric prostate MRI (mpMRI) and 18F-choline PET/CT in tumor segmentation for clinically significant prostate cancer. 18F-choline PET/CT and 3 T mpMRI were performed in 10 prospective subjects prior to prostatectomy. All subjects had a single biopsy-confirmed focus of Gleason ≥ 3+4 cancer. Two radiologists (readers 1 and 2) determined tumor boundaries based on in vivo mpMRI sequences, with clinical and pathologic data available. 18F-choline PET data were co-registered to T2-weighted 3D sequences and a semi-automatic segmentation routine was used to define tumor volumes. Registration of whole-mount surgical pathology to in vivo imaging was conducted utilizing two ex vivo prostate specimen MRIs, followed by gross sectioning of the specimens within a custom-made 3D-printed plastic mold. Overlap and similarity coefficients of manual segmentations (seg1, seg2) and 18F-choline-based segmented lesions (seg3) were compared to the pathologic reference standard. All segmentation methods greatly underestimated the true tumor volumes. Human readers (seg1, seg2) and the PET-based segmentation (seg3) underestimated an average of 79, 80, and 58% of the tumor volumes, respectively. Combining segmentation volumes (union of seg1, seg2, seg3 = seg4) decreased the mean underestimated tumor volume to 42% of the true tumor volume. When using the combined segmentation with 5 mm contour expansion, the mean underestimated tumor volume was significantly reduced to 0.03 ± 0.05 mL (2.04 ± 2.84%). Substantial safety margins up to 11–15 mm were needed to include all tumors when the initial segmentation boundaries were drawn by human readers or the semi-automated 18F-choline segmentation tool. Combining MR-based human segmentations with the metabolic information based on 18F-choline PET reduced the necessary safety margin to a maximum of 9 mm to cover all tumors entirely. To improve the outcome of focal therapies for significant prostate cancer, it is imperative to recognize the full extent of the underestimation of tumor volumes by mpMRI. Combining metabolic information from 18F-choline with MRI-based segmentation can improve tumor coverage. However, this approach requires confirmation in further clinical studies.Keywords
Funding Information
- United States Department of Defense (W81XWH-12-1-0597)
This publication has 45 references indexed in Scilit:
- Defining the threshold for significant versus insignificant prostate cancerNature Reviews Urology, 2013
- Challenges in accurate registration of 3-D medical imaging and histopathology in primary prostate cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Correlation of Magnetic Resonance Imaging Tumor Volume with HistopathologyJournal of Urology, 2012
- Semi-quantitative lymph node assessment of 18F-FDG PET/CT in locally advanced breast cancer: correlation with biological prognostic factorsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2012
- High‐intensity focused ultrasound (HIFU) for definitive treatment of prostate cancerBJU International, 2012
- Prognostic value of metabolic tumor burden on 18F-FDG PET in nonsurgical patients with non-small cell lung cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Physical and clinical performance of the mCT time-of-flight PET/CT scannerPhysics in Medicine & Biology, 2011
- Validation of Automatic Target Volume Definition as Demonstrated for 11C-Choline PET/CT of Human Prostate Cancer Using Multi-modality Fusion TechniquesAcademic Radiology, 2010
- Detection of Aggressive Primary Prostate Cancer with 11C-Choline PET/CT Using Multimodality Fusion TechniquesJournal of Nuclear Medicine, 2009
- Tissue-shrinkage Correction Factor in the Calculation of Prostate Cancer VolumeAmerican Journal of Surgical Pathology, 1996