Enhancing the Sensitivity of the Virus BioResistor by Overoxidation: Detecting IgG Antibodies
- 4 August 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (32) , 11259-11267
Abstract
The Virus BioResistor (VBR) is a biosensor capable of rapid and sensitive detection of small protein disease markers using a simple dip-and-read modality. For example, the bladder cancer-associated protein DJ-1 (22 kDa) can be detected in human urine within 1.0 min with a limit of detection (LOD) of 10 pM. The VBR uses engineered virus particles as receptors to recognize and selectively bind the protein of interest. These virus particles are entrained in a conductive poly(3,4-ethylenedioxythiophene) or PEDOT channel. The electrical impedance of the channel increases when the target protein is bound by the virus particles. But VBRs exhibit a sensitivity that is inversely related to the molecular weight of the protein target. Thus, large proteins, such as IgG antibodies (150 kDa), can be undetectable even at high concentrations. We demonstrate that the electrochemical overoxidation of the VBR’s PEDOT channel increases its electrical impedance, conferring enhanced sensitivity for both small and large proteins. Overoxidation makes possible the detection of two antibodies, undetectable at a normal VBR, with a limit of detection of 40 ng/mL (250 pM), and a dynamic range for quantitation extending to 600 ng/mL.Keywords
Funding Information
- National Cancer Institute (1R33CA206955-01)
- Chao Family Comprehensive Cancer Center
- National Science Foundation (CBET-1803314)
- PhageTech Inc (PHAGE-203015)
This publication has 24 references indexed in Scilit:
- Hybridized conducting polymer chemiresistive nano-sensorsNano Today, 2013
- Virus-Poly(3,4-ethylenedioxythiophene) Biocomposite FilmsLangmuir, 2012
- Point of Care Diagnostics: Status and FutureAnalytical Chemistry, 2011
- Virus−Poly(3,4-ethylenedioxythiophene) Composite Films for Impedance-Based BiosensingAnalytical Chemistry, 2011
- Electrodeposited PEDOT films on ITO with a flower-like hierarchical structureSynthetic Metals, 2010
- Robust fabrication of selective and reversible polymer coated carbon nanotube-based gas sensorsSensors and Actuators B: Chemical, 2010
- Cardiac biomarkers and the case for point-of-care testingClinical Biochemistry, 2009
- The effect of pH on the electrochemical over-oxidation in PEDOT:PSS filmsSolid State Ionics, 2007
- Criterion for Hill equation validity for description of biosensor calibration curvesAnalytica Chimica Acta, 2001
- Immuno-affinity partition of cells in aqueous polymer two-phase systemsJournal of Chromatography A, 1986