Exhaust ventilation in attached garages improves residential indoor air quality
Open Access
- 20 September 2016
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 27 (2) , 487-499
Abstract
Previous research has shown that indoor benzene levels in homes with attached garages are higher than homes without attached garages. Exhaust ventilation in attached garages is one possible intervention to reduce these concentrations. To evaluate the effectiveness of this intervention a randomized crossover study was conducted in 33 Ottawa homes in winter 2014. VOCs including BTEX (benzene, toluene, ethylbenzene and xylenes), nitrogen dioxide, carbon monoxide and air exchange rates were measured over four 48-hour periods when a garage exhaust fan was turned on or off. A blower door test conducted in each garage was used to determine the required exhaust fan flow rate to provide a depressurization of 5Pa in each garage relative to the home. When corrected for ambient concentrations, the fan decreased geometric mean indoor benzene concentrations from 1.04 to 0.40 μg/m3, or by 62% (pp<0.05) while having no impact on the home air exchange rate. This study provides evidence that mechanical exhaust ventilation in attached garages can reduce indoor concentrations of pollutants originating from within attached garages.Keywords
Funding Information
- Health Canada
- National Research Council Canada
This publication has 28 references indexed in Scilit:
- PM2.5, soot and NO2 indoor–outdoor relationships at homes, pre-schools and schools in Stockholm, SwedenAtmospheric Environment, 2010
- Housing Interventions and Control of Health-Related Chemical AgentsJournal of Public Health Management & Practice, 2010
- Predictors of Indoor Air Concentrations in Smoking and Non-Smoking ResidencesInternational Journal of Environmental Research and Public Health, 2010
- Predicting personal exposure of Windsor, Ontario residents to volatile organic compounds using indoor measurements and survey dataAtmospheric Environment, 2008
- Housing Characteristics and Indoor Concentrations of Selected Volatile Organic Compounds (VOCs) in Quebec City, CanadaIndoor and Built Environment, 2008
- Influence of basements, garages, and common hallways on indoor residential volatile organic compound concentrationsAtmospheric Environment, 2008
- Variations of formaldehyde and VOC levels during 3 years in new and older homesIndoor Air, 2006
- Environmental exposure to benzene: an update.Environmental Health Perspectives, 1996
- A survey of household products for volatile organic compoundsAtmospheric Environment. Part A. General Topics, 1992
- Detailed Description and Performance of a Passive Perfluorocarbon Tracer System for Building Ventilation and Air Exchange Measurements1986