Fitting Straight Lines with Replicated Observations by Linear Regression. III. Weighting Data
Authors:
- 2 August 2007
- journal article
- research article
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 37 (3) , 143-172
Abstract
The purpose of this article is to stress the importance of weighting in fitting straight lines with replicated observations. Nevertheless, single response data are also taken into account. Although the concept of weighting is treated on chemometric texts, a detailed procedure is not given. For this reason the present review covers the information concerning this topic. Ignoring non-constant variance (heterocedasticity) often leads to improper estimation and inference in a statistical model which quantifies a given relationship. There are two main solutions to remedy this problem: transform the data or perform a weighted least-squares regression analysis. Weighting with replication in homocedastic and heterodedastic condition, including transformation depending weights, and normalization of the weights are considered. Weighting of observations, however, presents a more difficult problem that has commonly been recognized. The review covers briefly topics as random errors and noise, modelling the variance as a function of the independent variable and variation of precision with concentration. By transforming variable it is possible to introduce non-linear terms to the mathematical framework of linear regression, in order to improve fit as to satisfy the necessary assumptions such as homocedasticity. However, transformation data, the analysis of variance and summary data analysis will be the subject of a future report. A number of applications concerning the uses of weighting in analytical chemistry and weighted linear regression are given in tabular form. The analytical, pharmaceutical, biochemical and clinical literature has been thoroughly revised.Keywords
This publication has 259 references indexed in Scilit:
- Determination of analytical error function for β-blockers as a possible weighting method for the estimation of the regression parametersJournal of Pharmaceutical and Biomedical Analysis, 1996
- A robotics-based liquid chromatographic assay for the measurement of atovaquone in plasmaJournal of Pharmaceutical and Biomedical Analysis, 1995
- Development and application of a calibration regression routine in conjunction with linear and non-linear chromatographic detector responsesJournal of Pharmaceutical and Biomedical Analysis, 1994
- Calibration and validation of linearity in chromatographic biopharmaceutical analysisJournal of Pharmaceutical and Biomedical Analysis, 1991
- Fitting heteroscedastic regression models to individual pharmacokinetic data using standard statistical softwareJournal of Pharmacokinetics and Biopharmaceutics, 1989
- Improvement of precision in spectrochemical analysis by correlation of intensity measurementsAnalytical and Bioanalytical Chemistry, 1986
- Abuse of the analyte addition technique in atomic absorption spectrometryAnalytical and Bioanalytical Chemistry, 1986
- General approach to handling nonuniform variance in assay calibrationJournal of Pharmaceutical and Biomedical Analysis, 1984
- Extended least squares nonlinear regression: A possible solution to the “choice of weights” problem in analysis of individual pharmacokinetic dataJournal of Pharmacokinetics and Biopharmaceutics, 1984
- Zum Problem der ?Genauigkeit? chemischer AnalysenMicrochimica Acta, 1968