Comparison of dynamic contour tonometry with Goldmann applanation tonometry in glaucoma practice
- 17 April 2009
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 87 (3) , 323-328
Abstract
To compare intraocular pressure (IOP) readings taken using dynamic contour tonometry (DCT) with IOP readings taken with Goldmann applanation tonometry (GAT) in eyes with glaucoma or ocular hypertension. The present study included 100 eyes in 100 patients with glaucoma or ocular hypertension. After pachymetry DCT and GAT were performed. Intraocular pressures as measured with DCT and GAT were compared with one another and with central corneal thickness (CCT). Mean DCT IOP measurements (20.1 +/- 4.3 mmHg) were significantly (p < 0.001) higher than GAT IOP values (17.9 +/- 4.7 mmHg). The mean difference between DCT and GAT measurements was 2.1 mmHg (range -3.4 to 9.7 mmHg). The difference followed a normal distribution. Measurements made with DCT and GAT correlated significantly with one another (Spearman's rho = 0.761, p < 0.001). Neither GAT nor DCT measurements showed a significant correlation with CCT (537 +/- 39 microm, range 458-656 microm). Multivariate regression analysis has shown that the difference between DCT and GAT is influenced significantly by ocular pulse amplitude (r = -0.334, p = 0.001) and it is not influenced by CCT (r = -0.106, p = 0.292). In eyes with glaucoma or ocular hypertension, DCT facilitates suitable and reliable IOP measurements which are in good concordance with GAT readings. Variation in CCT cannot by itself explain the differences in measurements taken with DCT and GAT in a number of eyes.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy SubjectsAmerican Journal of Ophthalmology, 2006
- Comparison of Dynamic Contour Tonometry With Goldman Applanation Tonometry Over a Wide Range of Central Corneal ThicknessJournal of Glaucoma, 2005
- Dynamic Contour Tonometry for Post-LASIK Intraocular Pressure MeasurementsKlinische Monatsblätter für Augenheilkunde, 2004
- Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometerActa Ophthalmologica Scandinavica, 2001
- Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readingsBritish Journal of Ophthalmology, 2001
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Ocular Hypertension and Central Corneal ThicknessOphthalmology, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975