Does the Addition of a Dynamic Pedicle Screw to a Fusion Segment Prevent Adjacent Segment Pathology in the Lumbar Spine?
Authors:
Open Access
- 31 October 2017
- journal article
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 11 (5) , 715-721
Abstract
Study DesignRetrospective clinical cohort study.Purpose To investigate whether the combined use of dynamic pedicle screws and polyaxial pedicle screws was effective on adjacent segment pathology (ASP).Overview of LiteratureVarious screw and rod models have been recently developed for preventing adjacent segment disease, and hybrid systems have been described along with posterior instrumentation in the fusion segment. In the literature, although the success of dynamic systems has been demonstrated in non-fusion posterior instrumentation, it remains unclear whether the addition of a screw-based dynamic system to a fusion segment would successfully prevent ASP in the long term.MethodsThe study included 101 patients who underwent surgery for degenerative spine diseases between 2007 and 2014 with lumbar stabilization that used either polyaxial pedicle screws alone or polyaxial pedicle screws plus dynamic stabilization screws (with hinged screw heads). These two patient groups were compared using retrospectively obtained postoperative new clinical findings, Oswestry disability index (ODI) scores, visual analog scale (VAS) scores, and radiological data.ResultsThe proportion of patients with ASP who were radiologically assessed was low (p 0.05).ConclusionsAlthough the combined use of dynamic screws and the static system was radiologically found to be effective for preventing ASP in patients who underwent lumbar fusion with posterior instrumentation, it did not completely eliminate ASP or result in a significant improvement in clinical ASP.Keywords
This publication has 18 references indexed in Scilit:
- Long-term Outcome After Monosegmental L4/5 Stabilization for Degenerative Spondylolisthesis With the Dynesys DeviceClinical Spine Surgery, 2016
- Indication for Spinal Fusion and the Risk of Adjacent Segment PathologySpine, 2012
- Do Lumbar Motion Preserving Devices Reduce the Risk of Adjacent Segment Pathology Compared With Fusion Surgery? A Systematic ReviewSpine, 2012
- Adjacent Level Disk Disease—Is it Really a Fusion Disease?Orthopedic Clinics of North America, 2011
- Influence of Dynesys System Screw Profile on Adjacent Segment and ScrewJournal of Spinal Disorders & Techniques, 2010
- Induction of early degeneration of the adjacent segment after posterior lumbar interbody fusion by excessive distraction of lumbar disc spaceJournal of Neurosurgery: Spine, 2010
- Pedicle screw-based dynamic stabilization of the thoracolumbar spine with the Cosmic®-system: a prospective observationActa Neurochirurgica, 2010
- Dynamic stabilization of the spine: a new classification systemTurkish Neurosurgery, 2009
- Disc Changes in the Bridged and Adjacent Segments After Dynesys Dynamic Stabilization System After Two YearsSpine, 2008
- Clinical Experience of the Dynamic Stabilization System for the Degenerative Spine DiseaseJournal of Korean Neurosurgical Society, 2008