Planar Functionalized Surfaces for Direct Immunoaffinity Desorption/Ionization Mass Spectrometry
- 1 January 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (1) , 270-278
Abstract
BACKGROUND: Recent studies show that the haptoglobin phenotype in individuals with diabetes mellitus is an important factor for predicting the risk of myocardial infarction, cardiovascular death, and stroke. Current methods for haptoglobin phenotyping include PCR and gel electrophoresis. A need exists for a reliable method for high-throughput clinical applications. Mass spectrometry (MS) can in principle provide fast phenotyping because haptoglobin α 1 and α 2, which define the phenotype, have different molecular masses. Because of the complexity of the serum matrix, an efficient and fast enrichment technique is necessary for an MS-based assay. METHODS: MALDI plates were functionalized by ambient ion landing of electrosprayed antihaptoglobin antibody. The array was deposited on standard indium tin oxide slides. Fast immunoaffinity enrichment was performed in situ on the plate, which was further analyzed by MALDI-TOF MS. The haptoglobin phenotype was determined from the spectra by embedded software script. RESULTS: The MALDI mass spectra showed ion signals of haptoglobin α subunits at m/z 9192 and at m/z 15 945. A cohort of 116 sera was analyzed and the reliability of the method was confirmed by analyzing the identical samples by Western blot. One hundred percent overlap of results between the direct immunoaffinity desorption/ionization MS and Western Blot analysis was found. CONCLUSIONS: MALDI plates modified by antihaptoglobin antibody using ambient ion landing achieve low nonspecific interactions and efficient MALDI ionization and are usable for quick haptoglobin phenotyping.Keywords
Funding Information
- Ministry of Education, Youth and Science (NPU LO1509)
- European Regional Development Fund (CZ.1.05/1.1.00/02.0109, CZ.1.07/2.3.00/30.0003)
- Charles Darwin University (UNCE 204025/2012)
This publication has 37 references indexed in Scilit:
- In‐situ enrichment of phosphopeptides on MALDI plates modified by ambient ion landingJournal of Mass Spectrometry, 2012
- Glycoproteomic analysis and molecular modeling of haptoglobin multimersElectrophoresis, 2011
- Enhanced in‐vitro blood compatibility of 316L stainless steel surfaces by reactive landing of hyaluronan ionsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- High efficiency in soft landing of biomolecular ions on a plasma‐treated metal surface: are double‐digit yields possible?Journal of Mass Spectrometry, 2005
- Preparative Soft and Reactive Landing of Gas-Phase Ions on Plasma-Treated Metal SurfacesAnalytical Chemistry, 2005
- Mass spectrometric protein structure characterization reveals cause of migration differences of haptoglobin α chains in two‐dimensional gel electrophoresisProteomics, 2004
- Preparative Linear Ion Trap Mass Spectrometer for Separation and Collection of Purified Proteins and Peptides in Arrays Using Ion Soft LandingAnalytical Chemistry, 2004
- Serum protein profiling by SELDI mass spectrometry: detection of multiple variants of serum amyloid alpha in renal cancer patientsLaboratory Investigation, 2004
- Preparing Protein Microarrays by Soft-Landing of Mass-Selected IonsScience, 2003
- Electrospray Deposition as a Method To Fabricate Functionally Active Protein FilmsAnalytical Chemistry, 1999