Combined effects of high atrial septal pacing and reactive atrial antitachycardia pacing for reducing atrial fibrillation in sick sinus syndrome
Open Access
- 26 June 2023
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (4) , 566-573
Abstract
Background: It is unknown whether atrial fibrillation (AF) burden varies by pacing site in patients with reactive atrial antitachycardia pacing (rATP). We aimed to compare AF burden in patients with high atrial septal pacing (HASp) via delivery catheter and right atrial appendage pacing (RAAp) in patients with sick sinus syndrome (SSS).Methods: We retrospectively identified 109 patients with a history of paroxysmal AF and SSS who had received dual‐chamber pacemaker implantation between January 2017 and December 2019, of whom 39 and 70 patients had HASp and RAAp, respectively. rATP was initiated after a 1‐month post‐implantation run‐in period.Results: Patients with HASp had a significantly shorter P‐wave duration during atrial pacing than those with RAAp (99.3 ± 10.4 vs. 116.0 ± 14.3 ms, p < .001). During the 3‐year follow‐up period, the incidence of an AF lasting longer than 1 or 7 days was significantly lower (hazard ratio [HR], 0.45; p = .016; HR, 0.24; p = .004) than in those with RAAp. The median time of AF/AT per day in the follow‐up periods was significantly shorter in the HASp group than in the RAAp group (10 vs. 18 min/day, p = .018). Atrial lead division did not occur in the HASp group during the follow‐up period.Conclusions: HASp via delivery catheter is as safe as RAAp, and HASp combined with rATP is effective for reducing AF burden in patients with SSS and paroxysmal AF.Keywords
This publication has 17 references indexed in Scilit:
- Interatrial septal pacing to suppress atrial fibrillation in patients with dual chamber pacemakers: A meta-analysis of randomized, controlled trialsInternational Journal of Cardiology, 2016
- A simple method for Bachmann's bundle pacing with indigenous modification of J-styletIndian Heart Journal, 2016
- Sinus Node and Atrial ArrhythmiasCirculation, 2016
- New-generation atrial antitachycardia pacing (Reactive ATP) is associated with reduced risk of persistent or permanent atrial fibrillation in patients with bradycardia: Results from the MINERVA randomized multicenter international trialHeart Rhythm, 2015
- Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trialEuropean Heart Journal, 2014
- Real-time dominant frequency mapping and ablation of dominant frequency sites in atrial fibrillation with left-to-right frequency gradients predicts long-term maintenance of sinus rhythmHeart Rhythm, 2009
- Presence of Left-to-Right Atrial Frequency Gradient in Paroxysmal but Not Persistent Atrial Fibrillation in HumansCirculation, 2004
- Effect of atrial antitachycardia pacing treatments in patients with an atrial defibrillator: randomised study comparing subthreshold and nominal pacing outputsHeart, 2002
- Prevention of Chronic Atrial Fibrillation by Pacing in the Region of Bachmann's Bundle: Results of a Multicenter Randomized TrialJournal of Cardiovascular Electrophysiology, 2001
- The Effect of the Atrial Pacing Site on the Total Atrial Activation TimePacing and Clinical Electrophysiology, 2001