Local bone quality affects the outcome of prosthetic total knee arthroplasty
Open Access
- 29 July 2015
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 34 (2) , 240-248
Abstract
Osteoporosis and osteoarthritis commonly coexist in the elderly. In patients undergoing prosthetic total knee arthroplasty (TKA), the bone quality around the knee joint may affect the safety of prosthetic implantation and consequently satisfaction with the surgical outcome. We recruited 50 postmenopausal women undergoing TKA for primary osteoarthritis; 43 completed the study protocol. The bone quality parameters of the operated knee, including bone mineral density assessed using dual‐energy X‐ray absorptiometry and microarchitecture variables assessed using micro‐computed tomography, were determined. Surgical outcomes were assessed according to immediate (R2 = 0.187–0.234, p < 0.01), the structural model index (R2 = 0.103–0.181, p < 0.05), and trabecular separation (R2 = 0.289–0.424, p < 0.05) were significantly associated with postoperative pain and improvement according to the KOOS. In conclusion, local bone quality, including mineral content and microarchitecture, affects the surgical outcome of TKA. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:240–248, 2016.Keywords
Funding Information
- National Science Council, Taiwan (NSC‐100‐2325‐B‐002‐060)
This publication has 36 references indexed in Scilit:
- Risk factor analysis for early femoral failure in metal-on-metal hip resurfacing arthroplasty: the effect of bone density and body mass indexJournal of Orthopaedic Surgery and Research, 2012
- Current Status of Developments and Applications of Micro-CTAnnual Review of Biomedical Engineering, 2011
- Role of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical BehaviorJournal of Bone and Mineral Research, 2009
- Relationship between trabecular bone structure and articular cartilage morphology and relaxation times in early OA of the knee joint using parallel MRI at 3 TOsteoarthritis and Cartilage, 2008
- Factors Affecting Flexion after Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- An estimate of the worldwide prevalence and disability associated with osteoporotic fracturesOsteoporosis International, 2006
- Peri-prosthetic bone mineral density after total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2006
- Quantification of Bone Microarchitecture with the Structure Model IndexComputer Methods in Biomechanics and Biomedical Engineering, 1997
- Changes in bone mineral density of the distal femur following uncemented total knee arthroplastyThe Journal of Arthroplasty, 1995
- The Cemented Unicondylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1992