One-Port Direct/Reverse Method for Characterizing VNA Calibration Standards
Open Access
- 30 June 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 64 (8) , 2631-2639
Abstract
This paper introduces a one-port method for estimating model parameters of vector network analyzer calibration standards. The method involves measuring the standards through an asymmetrical passive network connected in direct mode and then in reverse mode, and using these measurements to compute the S-parameters of the network. The free parameters of the calibration standards are estimated by minimizing a figure of merit based on the expected equality of the S-parameters of the network when used in direct and reverse modes. The capabilities of the method are demonstrated through simulations, and real measurements are used to estimate the actual offset delay of a 50-Ω calibration load that is assigned zero delay by the manufacturer. The estimated delay is 38.8 ps with a 1 σ uncertainty of 2.1 ps for this particular load. This result is verified through measurements of a terminated airline. The measurements agree better with theoretical models of the airline when the reference plane is calibrated using the new estimate for the load delay.Keywords
All Related Versions
Funding Information
- NSF through research awards for the Experiment to Detect the Global EoR Signature (AST-0905990, AST-1207761)
- NASA through Cooperative Agreements for the Lunar University Network for Astrophysics (NNA09DB30A)
- Nancy Grace Roman Technology Fellowship (NNX12AI17G)
This publication has 17 references indexed in Scilit:
- Study on the unknown thru calibration technique2014
- Characterizing calibration standards using one airline as a transfer standard2014
- A lower limit of Δz > 0.06 for the duration of the reionization epochNature, 2010
- Precision Calibration Coefficients for the Reciprocal ProcedureIEEE Microwave and Wireless Components Letters, 2007
- Characterising beadless air lines as reference artefacts for S -parameter measurements at RF and microwave frequenciesIEE Proceedings - Science, Measurement and Technology, 2006
- Why Reciprocal Procedure Works?2006
- Using simple calibration load models to improve accuracy of Vector Network Analyzer measurements2006
- The "unknown thru" calibration advantage2004
- Save The "Thru" in the A.N.A. Calibration1992
- Two-port network analyzer calibration using an unknown 'thru'IEEE Microwave and Guided Wave Letters, 1992