Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID)
Open Access
- 4 December 2012
- journal article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 5 (12) , 2981-2992
Abstract
The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH). Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF) system ("pump-and-probe" or "flow reactor") or the Comparative Reactivity Method (CRM) with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS). Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID). Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques. Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole) with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s), sensitivity (LOD 3–6 s−1) and overall uncertainty (25% in optimum conditions) for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests) it presents a viably economical alternative for groups interested in total OH reactivity observations.Keywords
All Related Versions
This publication has 32 references indexed in Scilit:
- Total OH reactivity measurements in Paris during the 2010 MEGAPOLI winter campaignAtmospheric Chemistry and Physics, 2012
- Reaction of Hydroxyl Radicals with C4H5N (Pyrrole): Temperature and Pressure Dependent Rate CoefficientsThe Journal of Physical Chemistry A, 2012
- Proton-Transfer Reaction Mass SpectrometryChemical Reviews, 2009
- Measurements of Volatile Organic Compounds Using Proton Transfer Reaction – Mass Spectrometry during the MILAGRO 2006 CampaignAtmospheric Chemistry and Physics, 2009
- The Tropical Forest and Fire Emissions Experiment: method evaluation of volatile organic compound emissions measured by PTR-MS, FTIR, and GC from tropical biomass burningAtmospheric Chemistry and Physics, 2007
- Inter-comparison between airborne measurements of methanol, acetonitrile and acetone using two differently configured PTR-MS instrumentsInternational Journal of Mass Spectrometry, 2004
- Missing OH Reactivity in a Forest: Evidence for Unknown Reactive Biogenic VOCsScience, 2004
- Total VOC reactivity in the planetary boundary layer: 1. Estimation by a pump and probe OH experimentJournal of Geophysical Research: Atmospheres, 2001
- Direct measurement of the total reaction rate of OH in the atmosphereAnalusis, 1999
- Films obtained by plasma polymerization of pyrroleThin Solid Films, 1999