No Increased Migration in Cups with Ceramic-on-Ceramic Bearing
Authors:
- Ming G LiMLMing G Li
- Niclas BörlinNBNiclas Börlin
- David J WoodDWDavid J Wood
- Bo NivbrantBNBo Nivbrant
- 1 July 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 448, 39-45
Abstract
Ceramic-on-ceramic hip replacements might stress the bone interface more than a metal-polyethylene because of material stiffness, microseparation, and sensitivity to impingement. To ascertain whether this potentially increased stress caused an increased cup migration we compared a ceramic-on-ceramic with a metal-on-polyethylene implant for cup migration. Sixty one patients (61 hips) undergoing THA for osteoarthritis were randomized to ceramic on ceramic (Ce/Ce) or cobalt-chromium on cross-linked polyethylene bearings (PE) in the same uncemented cup shell. Migration was followed with RSA. At 2 years we observed similar mean cup translations in the 3 directions (0.07-0.40 mm vs. 0.05-0.31 mm, Ce/Ce vs. PE), as well as similar rotations around the 3 axes (0.31-0.92 degrees vs. 0.57-1.40 degrees). WOMAC and SF-36 scores were also similar and no radiolucent lines or osteolysis found. The large migration seen in some cups in both implant groups will require close monitoring to ascertain the reasons. Mean proximal wear of the polyethylene liners measured 0.016 mm between 2 and 24 months. Our data suggest there is no increased cup migration in the ceramic-on-ceramic implant compared with the metal-on-polyethylene, and they seem an equally safe choice. However, the low wear measured with the more versatile and less expensive cross-linked polyethylene makes it a strong contender. Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 30 references indexed in Scilit:
- Alumina Ceramic Bearings for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose-response relationshipJournal of Orthopaedic Research, 2005
- THE OTTO AUFRANC AWARD: Highly Cross-linked Polyethylene in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- The influence of alumina and ultra-high molecular weight polyethylene particles on osteoblast–osteoclast cooperationBiomaterials, 2004
- Total hip replacement in younger patientsSurvival rate after avascular necrosis of the femoral headActa Orthopaedica, 2004
- Clinical and simulator wear study of alumina ceramic THR to 17 years and beyondJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Long‐term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Wear of conventional and cross‐linked ultra‐high‐molecular‐weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulatorJournal of Biomedical Materials Research, 2002
- Modern Ceramic-on-Ceramic Total Hip Systems in the United StatesClinical Orthopaedics and Related Research, 2000
- The MOS 36-ltem Short-Form Health Survey (SF-36)Medical Care, 1992