Surveillance of Fistula Function by Frequent Recirculation Measurements During High Efficiency Dialysis
Authors:
- Daniel SchneditzDSDaniel Schneditz
- Claudio RoncoCRClaudio Ronco
- Nathan W. LevinNLNathan W. Levin
- 1 July 2002
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 48 (4) , 394-397
Abstract
Native fistulae are assumed to remain patent even with low access flows and are likely to cause access recirculation in high efficiency treatments done with high extracorporeal blood flows. We tested whether frequent recirculation measurements could be used to identify fistulae at risk to fail because of low access flow. High efficiency hemodialysis was delivered by 2008H machines equipped with blood temperature monitors (BTM) to measure recirculation within the first hour of every hemodialysis treatment. Access flow was measured when two consecutive BTM recirculation measurements exceeded a threshold of 15%. If access flow was < 500 ml/min, patients were referred for fistula revision. Eighty patients with native AV fistulae were studied for a period of 6 months. Nine of 11 interventions performed during the whole observation period were triggered by a BTM recirculation above the threshold. Two fistulae thrombosed in spite of a BTM recirculation below the threshold. One fistula with a BTM recirculation above the threshold had an access flow of 1,550 ml/min and was not referred for revision. BTM recirculation to detect fistulae for revision is sensitive (81.8%) and specific (98.6%) in the presence of cardiopulmonary recirculation and can be done with minimum intervention and without loss of efficient treatment time.Keywords
This publication has 19 references indexed in Scilit:
- Noninvasive transcutaneous determination of access blood flow rateKidney International, 2001
- Sensitivity and Specificity of the Thermodilution Technique in Detection of Access RecirculationNephron, 2000
- Haemodialysis vascular access and fistula surveillance methods in The NetherlandsNephrology Dialysis Transplantation, 1999
- Management of vascular access for dialysis: an Italian surveyNephrology Dialysis Transplantation, 1999
- Vascular access for hemodialysisKidney International, 1999
- Validation of haemodialysis recirculation and access blood flow measured by thermodilutionNephrology Dialysis Transplantation, 1999
- New, angle-independent, low-cost Doppler system to measure blood flowThe American Journal of Surgery, 1998
- Vascular access survival among incident hemodialysis patients in the United StatesAmerican Journal of Kidney Diseases, 1997
- Theory and validation of access flow measurement by dilution technique during hemodialysisKidney International, 1995
- Causes of Hemodialysis Access FailureAdvances in Renal Replacement Therapy, 1994