Single step purification procedure for the rapid separation of equine leucocytes
- 1 December 1986
- journal article
- research article
- Published by Springer Nature in Veterinary Research Communications
- Vol. 10 (1) , 445-452
Abstract
Percoll gradients have been used to separate relatively pure populations of viable equine polymorphonuclear (PMN) and mononuclear (MN) cells. In preliminary studies, a continuous density gradient of 70% Percoll solution was used to separate two distinct leucocyte-rich bands. After measurement of the density of each band on the continuous gradient, discontinuous Percoll gradients, using 60% and 75% Percoll solutions, were used to provide a rapid means of separating PMN and MN cells. The yield of viable cells per ml of blood was 3.0×106 and 3.2×106 for MN and PMN cells, respectively. Corresponding values for recovery were 45% and 72%. The purity was 94% for PMNs and 99% for MNs.Keywords
This publication has 4 references indexed in Scilit:
- Isolation of equine neutrophils and analysis of functional characteristics by chemiluminescence and bactericidal assaysAmerican Journal of Veterinary Research, 1982
- Simulataneous isolation of bovine eosinophils and neutrophils on gradients of percollJournal of Immunological Methods, 1981
- Optimal conditions for simultaneous purification of mononuclear and polymorphonuclear leucocytes from human blood by the hypaque-ficoll methodJournal of Immunological Methods, 1980
- Isolation of mononuclear cells and granulocytes from human blood. Isolation of monuclear cells by one centrifugation, and of granulocytes by combining centrifugation and sedimentation at 1 g.1968