A Split-Wedge Anchorage for CFRP Cables: Numerical Model vs. Experimental Results
Open Access
Abstract
Fiber-reinforced polymers (FRPs) are widely used within civil structural applications either for structural retrofitting or new constructions. This is due to their appreciable mechanical properties such as high stiffness and strength, resistance to environmental effects, as well low density. Through the years, such peculiarities have encouraged researchers to apply FRP cables within the design of prestressing systems, where steel cables are systematically adopted. However, the brittleness intrinsic to FRP materials necessitates additional efforts to design the anchorage devices. In fact, tendons are here subjected to stress peaks, which need to be controlled in order to prevent the premature failure of the cable. Following this goal, authors recently studied an optimized split-wedge anchorage, for 12 mm-diameter pultruded-carbon-fiber-reinforced polymer (PCFRP) tendons, adopting double-angle (DA) wedges, and compared its performance with a single-angle (SA) wedge configuration. Tensile tests were performed on 3 SA and 2 DA prototypes, respectively, through a universal testing machine: the DA configuration exploited the average cable capacity (257 kN) once, denoting a maximum efficiency. The obtained experimental results are utilized, in the framework of the present work, to calibrate contact parameters of nonlinear finite element models. The presented numerical results helped to assess benefits of the proposed configurations and the behavior of the anchorage components: the DA configuration turned out to satisfactorily avoid stress peak superpositions on the cable, with a reduction in pressure in the loading end of the cable with respect to the SA model.Keywords
Funding Information
- WP2 CSLLPP/ReLUIS program
This publication has 30 references indexed in Scilit:
- Mechanical anchorage of FRP tendons – A literature reviewConstruction and Building Materials, 2012
- Numerical Simulation and Experimental Validation of an Integrated Sleeve-Wedge Anchorage for CFRP RodsJournal of Composites for Construction, 2011
- Numerical Optimization of a Compact and Reusable Pretensioning Anchorage System for CFRP TendonsJournal of Composites for Construction, 2011
- Novel Anchor System for CFRP Rod: Finite-Element and Mathematical ModelsJournal of Composites for Construction, 2007
- Development and Assessment of a New CFRP Rod–Anchor System for Prestressed ConcreteApplied Composite Materials, 2006
- FEM and mathematical models of the interfacial contact behaviour of CFRP-metal couplesComposite Structures, 2006
- Coefficient of friction and wear of a carbon fiber epoxy matrix compositeWear, 2004
- Design and evaluation of a wedge-type anchor for fibre reinforced polymer tendonsCanadian Journal of Civil Engineering, 2000
- A new steel anchorage system for post-tensioning applications using carbon fibre reinforced plastic tendonsCanadian Journal of Civil Engineering, 1998
- Structural use of parafil ropesConstruction and Building Materials, 1987