Applications of Isolated-Check Visual Evoked Potential in Early Stage of Open-Angle Glaucoma Patients
Authors:
Open Access
- 20 October 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 131 (20) , 2439-2446
Abstract
Detect visual function abnormalities in early-stage OAG and to explore potential related factors. Methods: This was a cross-sectional study. Thirty-seven OAG patients with early-stage visual field loss (mean deviation ≥ −6.00 dB) detected by the Humphrey Field Analyzer (30-2 SITA program) and 26 controls were included in this study. Optical coherence tomography (OCT) was used to detect retinal nerve fiber layer (RNFL) defects. The icVEP preferentially evaluates the magnocellular-ON pathway. VEPs were recorded and signal-to-noise ratios (SNRs) were derived based on multivariate analysis. Eyes that yielded an SNR ≤1 were considered abnormal. Receiver operating characteristic (ROC) curve analysis was used to estimate the accuracy of group classification. Correlations between SNRs and related factors were analyzed. Results: Based on an SNR criterion of 1, the icVEP had a sensitivity of 62.2% and a specificity of 92.3% for diagnosing early-stage OAG with 74.6% classification accuracy. The ROC curve analysis, however, suggested that an SNR criterion of 0.93 would produce the highest classification accuracy (77.3%). Both RNFL thinning in the temporal superior quadrant on OCT and number of abnormal test points in the central 11° visual field (pattern deviation, P < 0.5%) significantly correlated with the SNR (P < 0.05). Conclusions: The icVEP detected visual function abnormalities in approximately 3/5 of eyes with early-stage OAG with greater than 90% specificity. SNR correlated with both a decrease in RNFL thickness and severity of central visual field loss....Keywords
This publication has 34 references indexed in Scilit:
- The Nature of Macular Damage in Glaucoma as Revealed by Averaging Optical Coherence Tomography DataTranslational Vision Science & Technology, 2012
- Initial Arcuate Defects within the Central 10 Degrees in GlaucomaInvestigative Ophthalmology & Visual Science, 2011
- Potential of Stratus Optical Coherence Tomography for Detecting Early Glaucoma in Perimetrically Normal Eyes of Open-angle Glaucoma Patients With Unilateral Visual Field LossJournal of Glaucoma, 2010
- Novel electrophysiological instrument for rapid and objective assessment of magnocellular deficits associated with glaucomaDocumenta Ophthalmologica, 2008
- Frequency Doubling Technology Perimetry in Open-angle Glaucoma Eyes With Hemifield Visual Field Damage: Comparison of High-tension and Normal-tension GroupsJournal of Glaucoma, 2007
- Frequency doubling technology perimetry abnormalities as predictors of glaucomatous visual field lossAmerican Journal of Ophthalmology, 2004
- Normative data for a user-friendly paradigm for pattern electroretinogram recordingOphthalmology, 2004
- Glaucomatous optic disc changes in the contralateral eye of unilateral normal pressure glaucoma patients11The authors have no proprietary interest in the development or marketing of this or a competing instrument.Ophthalmology, 2000
- Contrast-dependent responses in the human visual system: Childhood through adulthoodInternational Journal of Neuroscience, 1995
- The discharge of impulses in the optic nerve of Pecten in response to illumination of the eyeJournal of Cellular and Comparative Physiology, 1938