To investigate effects of stent flexibility on 6 months' clinical and angiographic outcome in long stented lesions. A total of 44 genuine coronary artery lesions (lesion length >20 mm and < or =30 mm) were randomized to implantation with a 30 mm long flexible coiled stainless steel stent (Freedom Force, Global Therapeutics) (n = 23) or a 30 mm long stiff tubular stainless steel stent (Crown, Johnson & Johnson) (n = 21). Target vessel revascularization was performed in 10 patients (45%) in the Freedom Force stent group, and in 7 patients (33%) in the Crown stent group (ns). No significant differences concerning minimum lumen diameter (MLD), early gain, late loss or binary restenosis rate were seen. In the Freedom Force stent group all restenoses were located within the stent. In the Crown stent group three (27%) of the restenoses were located at the edge of the stent (ns). In a limited number of patients no significant differences could be detected in clinical or angiographic parameters between patients treated with long tubular or long coiled stents.Keywords
This publication has 11 references indexed in Scilit:
- Endoluminal Beta-Radiation Therapy for the Prevention of Coronary Restenosis after Balloon AngioplastyNew England Journal of Medicine, 2001
- Lack of Neointimal Proliferation After Implantation of Sirolimus-Coated Stents in Human Coronary ArteriesCirculation, 2001
- Early and long-term results of stenting of diffuse coronary artery diseaseThe American Journal of Cardiology, 2000
- Randomized Comparison of GR-II Stent and Palmaz-Schatz Stent for Elective Treatment of Coronary StenosesCirculation, 2000
- Percutaneous transluminal coronary angioplasty of chronic total occlusions. determinants of primary success and long-term clinical outcomeCatheterization and Cardiovascular Interventions, 2000
- Comparison of immediate and follow-up results of the short and long NIR stent with the palmaz-schatz stentThe American Journal of Cardiology, 1999
- Stented segment length as an independent predictor of restenosisJACC, 1999
- Influence of lesion length on restenosis after coronary stent placementThe American Journal of Cardiology, 1999
- Stenting in chronic coronary occlusion (SICCO): A randomized, controlled trial of adding stent implantation after successful angioplastyJACC, 1996
- Does length or eccentricity of coronary stenoses influence the outcome of transluminal dilatation?Circulation, 1983