The physiologic effect of the pneumoperitoneum on radiofrequency ablation
Authors:
- 1 January 2004
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 18 (1) , 35-38
Abstract
Background: Radiofrequency ablation (RFA) is gaining widespread acceptance as a safe and effective method for liver tumor ablation. Complete tumor ablation is essential for the success of the procedure. Multiple modalities have been explored in an effort to increase the size of the lesion created by RFA. The purpose of this study was to determine the physiologic effects of the pneumoperitoneum on RFA lesion size. Methods: A total of 32 RFA lesions were created in eight pigs. After the induction of anesthesia, pneumoperitoneums of 2, 12, and 24 mmHg were established sequentially in each animal. After an equilibration period of 2 min, RF was administered with a constant saline-infused (0.9%) needle at 25 W for 3 min. In subsequent and complementary experiments, both before and during RF administration at each intraperitoneal pressure (IPP), Doppler flow was measured by laparoscopic ultrasound in the portal vein and hepatic artery while blood pressure was monitored by a femoral arterial line. The animals were then killed humanely and the livers were harvested. Measurements were taken in three dimensions of the ablated areas, and the volume was calculated. Statistical analyses were performed using analysis of variance (ANOVA) and repeated measures test. Results: The average volumes of the lesions (in cm3) were 3.1 ± 1.8, 5.2 ± 1.7, and 6.7 ± 3.3 for IPP of 2, 12 and 24 mmHg, respectively; there was a significant difference between the area of lesion at an IPP of 2 mmHg and an IPP of 24 mmHg (p < 0.05). Blood flow in the portal vein also decreased significantly from 1.8 ± 0.6, 0.98 ± 0.5, and 0.43 ± 0.2 at IPP of 2, 12, and 24 mmHg, respectively (p < 0.001). Hepatic artery blood flow and peripheral blood pressure did not change significantly in the respective IPP groups. Conclusions: This study indicates that the volume of liver ablated by RF can be increased by augmenting the IPP. Our data support the theory that a decrease in portal blood flow results in decreased heat dissipation during RFA. The laparoscopic approach to RFA offers the advantage of allowing control of the IPP, which may result in a larger volume of ablated tissue per treatment than can be achieved with the percutaneous technique. These preliminary data on normal hepatic tissue must be confirmed clinically in the setting of hepatic tumors.Keywords
This publication has 19 references indexed in Scilit:
- Effect of Vascular Occlusion on Radiofrequency Ablation of the LiverAmerican Journal of Roentgenology, 2001
- Radiofrequency Liver AblationAmerican Journal of Roentgenology, 2001
- Comparison of the effects of in-vivo thermal ablation of pig liver by microwave and radiofrequency coagulationJournal of Hepato-Biliary-Pancreatic Surgery, 2000
- Cryosurgical Ablation and Radiofrequency Ablation for Unresectable Hepatic Malignant NeoplasmsArchives of Surgery, 2000
- Laparoscopic radiofrequency ablation of primary and metastaticliver tumorsSurgical Endoscopy, 2000
- Radiofrequency Ablation Lesions in a Pig Liver ModelJournal of Surgical Research, 1999
- Clinical short-term results of radiofrequency ablation in primary and secondary liver tumorsThe American Journal of Surgery, 1999
- Radiofrequency Ablation of Porcine Liver In VivoAnnals of Surgery, 1998
- Percutaneous Radiofrequency Tissue Ablation: Does Perfusion-mediated Tissue Cooling Limit Coagulation Necrosis?Journal of Vascular and Interventional Radiology, 1998
- Superior Staging of Liver Tumors with Laparoscopy and Laparoscopic UltrasoundAnnals of Surgery, 1994