Intravoxel incoherent motion diffusion-weighted MR imaging of gliomas: feasibility of the method and initial results
- 14 July 2013
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 55 (10) , 1189-1196
Abstract
Introduction The purpose of this study was to evaluate the feasibility of intravoxel incoherent motion (IVIM) imaging and its value in differentiating the histologic grade among human gliomas. Methods The IVIM model generated parametric images for apparent diffusion coefficient ADC, slow diffusion coefficient D (or D slow), fast diffusion coefficient D* (or D fast), and fractional perfusion-related volume f in 22 patients with gliomas (WHO grade II–IV) using monopolar Stejskal–Tanner diffusion-weighted imaging (DWI) scheme and 14 b values ranging from 0 s/mm2 to a maximum of 1,300 s/mm2. A region-of-interest analysis on the tumor as well as in the white matter was conducted. The parameter values were tested for significant differences. The repeatability of the measurements was tested by coefficient of variation and Bland–Altman plots. Results D, D*, and f in the high-grade gliomas demonstrated significant differences compared to the healthy white matter. D* and f showed a significant difference between low- and high-grade gliomas. D tended to be slightly lower in the WHO grade II compared to WHO grade III–IV tumors. f and D* demonstrated higher coefficients of variation than the ADC and D in tumor. The Bland–Altman plots demonstrated satisfactory results without any outliers outside the mean ± 1.96 standard deviation. Conclusion The IVIM-fitted post-processing of DWI-signal decay in human gliomas could show significantly different values of fractional perfusion-related volume and fast diffusion coefficient between low- and high-grade tumors, which might enable a noninvasive WHO grading in vivo.Keywords
This publication has 28 references indexed in Scilit:
- Intravoxel incoherent motion MR imaging for prostate cancer: An evaluation of perfusion fraction and diffusion coefficient derived from different b‐value combinationsMagnetic Resonance in Medicine, 2012
- Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilitiesMagnetic Resonance Materials in Physics, Biology and Medicine, 2009
- Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-ValuesInvestigative Radiology, 2009
- Evaluation of hepatic lesions and hepatic parenchyma using diffusion‐weighted echo‐planar MR with three values of gradient b‐factorJournal of Magnetic Resonance Imaging, 2006
- Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniquesBritish Journal of Radiology, 2006
- Water diffusion heterogeneity index in the human brain is insensitive to the orientation of applied magnetic field gradientsMagnetic Resonance in Medicine, 2006
- Characterization of continuously distributed cortical water diffusion rates with a stretched‐exponential modelMagnetic Resonance in Medicine, 2003
- Effects of equilibrium exchange on diffusion‐weighted NMR signals: The diffusigraphic “shutter‐speed”Magnetic Resonance in Medicine, 2003
- Diffusion parameters of the extracellular space in human gliomasGlia, 2003
- Does IVIM measure classical perfusion?Magnetic Resonance in Medicine, 1990