Statistical Considerations for Assessment of Bioanalytical Incurred Sample Reproducibility
Author:
- 8 August 2009
- journal article
- Published by Springer Nature in The AAPS Journal
- Vol. 11 (3) , 570-580
Abstract
Bioanalytical method validation is generally conducted using standards and quality control (QC) samples which are prepared to be as similar as possible to the study samples (incurred samples) which are to be analyzed. However, there are a variety of circumstances in which the performance of a bioanalytical method when using standards and QCs may not adequately approximate that when using incurred samples. The objective of incurred sample reproducibility (ISR) testing is to demonstrate that a bioanalytical method will produce consistent results from study samples when re-analyzed on a separate occasion. The Third American Association of Pharmaceutical Scientists (AAPS)/Food and Drug Administration (FDA) Bioanalytical Workshop and subsequent workshops have led to widespread industry adoption of the so-called “4–6–20” rule for assessing incurred sample reproducibility (i.e. at least 66.7% of the re-analyzed incurred samples must agree within ±20% of the original result), though the performance of this rule in the context of ISR testing has not yet been evaluated. This paper evaluates the performance of the 4–6–20 rule, provides general recommendations and guidance on appropriate experimental designs and sample sizes for ISR testing, discusses the impact of repeated ISR testing across multiple clinical studies, and proposes alternative acceptance criteria for ISR testing based on formal statistical methodology.Keywords
This publication has 12 references indexed in Scilit:
- Workshop Report and Follow-Up—AAPS Workshop on Current Topics in GLP Bioanalysis: Assay Reproducibility for Incurred Samples—Implications of Crystal City RecommendationsThe AAPS Journal, 2009
- Confirmatory reanalysis of incurred bioanalytical samplesThe AAPS Journal, 2007
- Quantitative Bioanalytical Methods Validation and Implementation: Best Practices for Chromatographic and Ligand Binding AssaysPharmaceutical Research, 2007
- Risk management for analytical methods based on the total error concept: Conciliating the objectives of the pre-study and in-study validation phasesChemometrics and Intelligent Laboratory Systems, 2007
- A Total Error Approach for the Validation of Quantitative Analytical MethodsPharmaceutical Research, 2007
- Workshop/conference report—Quantitative bioanalytical methods validation and implementation: Best practices for chromatographic and ligand binding assaysThe AAPS Journal, 2007
- Statistical Methods for Assessing Stability of Compounds in Whole Blood for Clinical BioanalysisDrug Information Journal, 2001
- Estimation of the percentage of a normal distribution lying outside a specified intervalCommunications in Statistics - Theory and Methods, 1988
- Two-Sided Tolerance Limits for Normal Populations, Some ImprovementsJournal of the American Statistical Association, 1969
- Tolerance Limits for a Normal DistributionThe Annals of Mathematical Statistics, 1946