Comparison of non-contact infrared thermometry and rectal thermometry in cats
Authors:
- 10 July 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 18 (10) , 798-803
Abstract
Objectives: Body temperature is commonly used for assessing health and identifying infectious diseases in cats. Rectal thermometry, the most commonly used method, is stressful, invasive and time consuming. Non-contact infrared thermometry (NIRT) has been used with mixed success to measure temperature in humans and other species. The purpose of this study was to determine if NIRT measurements were comparable to rectal temperature measurements or, if not highly correlated, could at least identify cats in the hypothermic or hyperthermic range in need of further evaluation. Methods: From a total of six NIRT devices and 15 anatomic sites, three devices and three sites (pinna, gingiva and perineum) with the highest correlation to rectal temperature were selected for further study. Measurements were made in 188 adult cats housed indoors at animal shelters, veterinary clinics and private homes across a wide range of body temperatures and compared with rectal temperatures. Results: Bland–Altman analysis revealed poor agreement between NIRT and rectal thermometry. The mean NIRT measurements ranged from 0.7–1.3°C below the mean rectal measurements, but the effect was not consistent; NIRT measurements tended to exceed rectal measurements in hypothermic cats and fall below rectal measurements in normothermic and hyperthermic cats. Conclusions and relevance: The accuracy of temperature measurements using NIRT devices is not reliable for clinical use in cats.Keywords
This publication has 12 references indexed in Scilit:
- Comparison of axillary, tympanic membrane and rectal temperature measurement in catsJournal of Feline Medicine and Surgery, 2015
- Airport screening for EbolaBMJ, 2014
- Accuracy of tympanic and forehead thermometers in private paediatric practiceActa Paediatrica, 2013
- Clinical Accuracy of Tympanic Thermometer and Noncontact Infrared Skin Thermometer in Pediatric PracticePediatric Emergency Care, 2013
- Agreement between auricular and rectal measurements of body temperature in healthy catsJournal of Feline Medicine and Surgery, 2012
- Agreement between axillary, tympanic, and mid-forehead body temperature measurements in adult emergency department patientsEuropean Journal of Emergency Medicine, 2012
- Clinical accuracy of a non‐contact infrared skin thermometer in paediatric practiceChild: Care, Health and Development, 2011
- A Comparative Study of Non-contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the HorseJournal of Equine Veterinary Science, 2011
- Comparison of Body Temperature in Cats Using a Veterinary Infrared Thermometer and a Digital Rectal ThermometerJournal of the American Animal Hospital Association, 2004
- Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgeryCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1998