CMOS Imaging of Temperature Effects on Pin-Printed Xerogel Sensor Microarrays
- 10 December 2010
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 5 (2) , 189-196
Abstract
In this paper, we study the effect of temperature on the operation and performance of a xerogel-based sensor microarrays coupled to a complementary metal-oxide semiconductor (CMOS) imager integrated circuit (IC) that images the photoluminescence response from the sensor microarray. The CMOS imager uses a 32 × 32 (1024 elements) array of active pixel sensors and each pixel includes a high-gain phototransistor to convert the detected optical signals into electrical currents. A correlated double sampling circuit and pixel address/digital control/signal integration circuit are also implemented on-chip. The CMOS imager data are read out as a serial coded signal. The sensor system uses a light-emitting diode to excite target analyte responsive organometallic luminophores doped within discrete xerogel-based sensor elements. As a proto type, we developed a 3 × 3 (9 elements) array of oxygen (O 2 ) sensors. Each group of three sensor elements in the array (arranged in a column) is designed to provide a different and specific sensitivity to the target gaseous O 2 concentration. This property of multiple sensitivities is achieved by using a mix of two O 2 sensitive luminophores in each pin-printed xerogel sensor element. The CMOS imager is designed to be low noise and consumes a static power of 320.4 μW and an average dynamic power of 624.6 μW when operating at 100-Hz sampling frequency and 1.8-V dc power supply.Keywords
This publication has 28 references indexed in Scilit:
- Temporal Noise Analysis and Reduction Method in CMOS Image Sensor Readout CircuitIEEE Transactions on Electron Devices, 2009
- Sensitivity-Enhanced CMOS Phase Luminometry System Using Xerogel-Based SensorsIEEE Transactions on Biomedical Circuits and Systems, 2009
- CMOS integrated luminescence oxygen multi-sensor systemElectronics Letters, 2007
- Optical sensors and biosensors based on sol–gel filmsTalanta, 2007
- CMOS-Based Phase Fluorometric Oxygen Sensor SystemIEEE Transactions on Circuits and Systems I: Regular Papers, 2007
- A temperature-controlled complementary metal oxide semiconductor cameraProceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 2004
- A comparison of imaging methods for use in an array biosensorBiosensors and Bioelectronics, 2002
- Peer Reviewed: Oxygen Sensors Based on Luminescence Quenching.Analytical Chemistry, 1999
- Optical Chemical Sensors Based on Sol-Gel Materials: Recent Advances and Critical IssuesJournal of Sol-Gel Science and Technology, 1997
- Sol-gel encapsulation methods for biosensorsAnalytical Chemistry, 1994