Measurement of lipoprotein(a) via a novel point of care approach with comparison to established laboratory assays
Open Access
- 15 December 2025
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (5) , 1161-1168
Abstract
Objectives: Lipoprotein(a) is an atherogenic particle causative of atherosclerotic cardiovascular disease. Novel treatments have been developed that lower lipoprotein(a) to unprecedented levels with cardiovascular outcomes trials ongoing. Many guidelines recommend testing once in the lifetime of everyone, but testing rates remain low. In this study we compare a lipoprotein(a) point of care testing device to laboratory analysers and assess its performance. Methods: Lipoprotein(a) concentrations on residual patient samples measured on the Randox and Roche assays were compared to a novel point of care device, iProtin. Furthermore, assessment of iProtin performance characteristics were performed, including intra- and inter-assay coefficient of variation and dilutional studies. Results: Lipoprotein(a) concentrations measured on the Randox and Roche assays showed strong correlation with iProtin. Regression analysis using Passing-Bablock showed the best fits for iProtin based on 58 serum samples were: 1.15 × Randox + 7.28 nmol/L and 1.02 × Roche + 17.54 nmol/L. The R 2 values for Randox/iProtin and Roche/iProtin were 0.906 and 0.912 respectively. Correlation between Roche and Randox showed Roche=1.15 × Randox − 13.33 nmol/L with an R 2 value of 0.973. Inter-assay coefficient of variation of the iProtin device showed a day-to-day imprecision over 5 days of 15.5 % (low concentration quality control) and 6.2 % (high concentration quality control). Within day imprecision was 13.2 % (lower concentration patient sample) and 14.3 % (higher concentration patient sample). Conclusions: Point of care testing could be a complimentary option to laboratory testing of lipoprotein(a), especially in remote areas. It may help (re-)stratify cardiovascular risk and help tailor treatment decisions.Keywords
This publication has 29 references indexed in Scilit:
- Interlaboratory comparison of serum lipoprotein(a) analytical results across clinical assays—Steps toward standardizationJournal of Clinical Lipidology, 2025
- Temporal trends in lipoprotein(a) testing among United States veterans from 2014 to 2023American Journal of Preventive Cardiology, 2024
- Real-world impact of transitioning from one lipoprotein(a) assay to another in a clinical settingAmerican Journal of Preventive Cardiology, 2024
- Time Trends and Missed Opportunities in Lipoprotein(a) Testing Amongst Young Patients With ST-Elevation Myocardial Infarction in Western AustraliaHeart, Lung and Circulation, 2024
- Chest Pain Management Using Prehospital Point-of-Care Troponin and Paramedic Risk AssessmentJAMA Internal Medicine, 2023
- Australian Atherosclerosis Society Position Statement on Lipoprotein(a): Clinical and Implementation RecommendationsHeart, Lung and Circulation, 2023
- Lipoprotein(a)2023
- Lipoprotein(a) measurement issues: Are we making a mountain out of a molehill?Atherosclerosis, 2022
- Quantifying apolipoprotein(a) in the era of proteoforms and precision medicineClinica Chimica Acta, 2020
- Comparison of lipoprotein (a) serum concentrations measured by six commercially available immunoassaysAtherosclerosis, 2019