National External Quality Assessment Scheme for Lymphocyte Immunophenotyping in Belgium
Authors:
- Marjan Van BlerkMBMarjan Van Blerk
- Michel BernierMBMichel Bernier
- Xavier BossuytXBXavier Bossuyt
- Bernard ChatelainBCBernard Chatelain
- Jean-Luc D'HAutcourtJDJean-Luc D'HAutcourt
- Christian DemanetCDChristian Demanet
- Luc KestensLKLuc Kestens
- Dirk Van BockstaeleDBDirk Van Bockstaele
- Tania CrucittiTCTania Crucitti
- Jean-Claude LibeerJLJean-Claude Libeer
- 24 January 2003
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 41 (3) , 323-330
Abstract
In 2000, the Belgian Scientific Institute of Public Health introduced a voluntary external quality assessment scheme for lymphocyte immunophenotyping. This paper provides an analysis of the first six surveys. Specimens consisted of fresh EDTA-anticoagulated whole blood and were sent by overnight mail. The 41 participants were surveyed for methodology and were asked to report white blood cell count, percentage of lymphocytes, and percentages and absolute numbers of CD3+, CD4+, CD8+, and CD19+ cells. Median intralaboratory coefficients of variation were 1.0, 1.3, 1.7, and 3.2% for CD3+, CD4+, CD8+, and CD19+ cell percentages, respectively. Interlaboratory variability was consistently lower than 6.5% for CD3+ and CD4+CD3+ cell percentages, and lower than 9.5% for CD8+CD3+ cell percentages. Median coefficients of variation for the absolute values were higher, ranging from 10.1% for CD4+CD3+ cells to 16.5% for CD19+ cells. The percentage of CD4+CD3+ and CD8+ CD3+ cells was in several samples significantly lower than the percentage of total CD4+ and CD8+ cells. The number of laboratories measuring total CD4+ and CD8+ cells decreased by 30% during the programme. Between-laboratory variability remained stable over time. Analysis of individual laboratory performance indicated that some laboratories markedly improved their results.Keywords
This publication has 18 references indexed in Scilit:
- UK NEQAS for leucocyte immunophenotyping: the first 10 yearsJournal of Clinical Pathology, 2001
- Belgian Consensus Recommendations for Flow Cytometric Immunophenotyping.Acta Clinica Belgica, 1999
- Evolution of leukocyte immunophenotyping as influenced by the HIV/AIDS pandemic: A short history of the development of gating strategies for CD4+ T-cell enumerationCytometry, 1997
- Analysis of variation in results of flow cytometric lymphocyte immunophenotyping in a multicenter studyCytometry, 1997
- Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: Results from the UK NEQAS immune monitoring schemeCytometry, 1996
- Use of CD45 fluorescence and side-scatter characteristics for gating lymphocytes when using the whole blood lysis procedure and flow cytometryCytometry, 1996
- Interlaboratory quality assessment of lymphocyte phenotyping. Etalonorme 1990–1992 surveysBiology of the Cell, 1993
- Consistency of routine measurements of CD4+, CD8+ peripheral blood lymphocytesJournal of Immunological Methods, 1992
- Effect of type of haematology analyser on CD4 countThe Lancet, 1992
- Results of the flow cytometry ACTG quality control program: Analysis and findingsClinical Immunology and Immunopathology, 1989