The impact of venous occlusion per se on forearm muscle blood flow: implications for the near‐infrared spectroscopy venous occlusion technique
- 2 October 2015
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (3) , 293-298
Abstract
Summary: The purpose of this study was to examine the effect of venous occlusion per se on forearm muscle blood flow, as determined by the near‐infrared spectroscopy (NIRS) venous occlusion technique (NIRS‐VOT). NIRS data were obtained from the flexor digitorum superficialis (FDS) muscle on the dominant arm of 16 young, ostensibly healthy participants (14 men and two women; 30 ± 6 year; 73 ± 7 kg). Participants completed a series of five venous occlusion trials while seated at rest, and a series of 12 venous occlusion trials during a reactive hyperaemia induced by 5 min of forearm arterial occlusion. The NIRS‐VOT was used to assess FDS muscle blood flow (), beat‐by‐beat, over the first four cardiac beats during venous occlusions. was also reported as a cumulative value, wherein the first two, first three and first four cardiac beats were used to calculate muscle blood flow. We observed that was highest when calculated over the first cardiac beat during venous occlusions performed at rest and throughout reactive hyperaemia (Pper se affects the measurement of via the NIRS‐VOT. Accordingly, it is recommended that is determined over the first cardiac beat when using the NIRS‐VOT to assess microvascular blood flow of human forearm muscles.Keywords
Funding Information
- Griffith University
This publication has 29 references indexed in Scilit:
- Characterization and reproducibility of forearm arterial flow during reactive hyperemiaPhysiological Measurement, 2010
- Forearm plethysmography in the assessment of vascular tone and resistance vasculature design: new methodological insightsActa Physiologica, 2006
- Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopyJournal of Biomedical Optics, 1997
- Computerized evaluation of the peripheral blood flow during maximal vasodilatation in humans using venous occlusion plethysmographyClinical Physiology and Functional Imaging, 1995
- Time-resolved spectroscopy of the human forearmJournal of Photochemistry and Photobiology B: Biology, 1992
- Evidence for a local sympathetic venoarteriolar "reflex" in the dog hindleg.Circulation Research, 1983
- Effect of vein pump activation upon muscle blood flow and venous pressure in the human legActa Physiologica Scandinavica, 1982
- Measurement of Arterial and Venous Reactivity by an Advanced Strain Gauge PlethysmographAngiology, 1979
- Local Reflex in Microcirculation in Human Skeletal MuscleActa Physiologica Scandinavica, 1977
- Effect of Small Degrees of Venous Distension on the Apparent Inflow Rate of Blood to the Human CalfCirculation Research, 1957