Infrared‐assisted tryptic proteolysis for peptide mapping
Authors:
- 4 July 2008
- journal article
- technology
- Published by Wiley in Proteomics
- Vol. 8 (13) , 2579-2582
Abstract
In this report, infrared (IR) radiation was employed to enhance the efficiency of tryptic proteolysis for peptide mapping. Protein solutions containing trypsin in sealed transparent Eppendorf tubes were allowed to digest under an IR lamp at 37ºC. The feasibility and performance of the novel proteolysis approach were demonstrated by the digestion of BSA and myoglobin (MYO) and the digestion time was significantly reduced to 5 min. The obtained digests were identified by MALDI‐TOF MS with the sequence coverages of 69% (BSA) and 90% (MYO) that were much better than those obtained by conventional in‐solution tryptic digestion. The present IR‐assisted proteolysis strategy is simple and efficient, offering great promise for high‐throughput protein identification.Keywords
This publication has 14 references indexed in Scilit:
- Trypsin‐immobilized fiber core in syringe needle for highly efficient proteolysisProteomics, 2008
- Development of microwave‐assisted protein digestion based on trypsin‐immobilized magnetic microspheres for highly efficient proteolysis followed by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry analysisRapid Communications in Mass Spectrometry, 2007
- Fiber‐packed channel bioreactor for microfluidic protein digestionProteomics, 2007
- Immobilization of Trypsin on Superparamagnetic Nanoparticles for Rapid and Effective ProteolysisJournal of Proteome Research, 2007
- Assembly‐Controlled Biocompatible Interface on a Microchip: Strategy to Highly Efficient ProteolysisChemistry – A European Journal, 2006
- Detection and Identification of Sub-nanogram Levels of Protein in a NanoLC-Trypsin-MS SystemJournal of Proteome Research, 2006
- Titania and Alumina Sol−Gel-Derived Microfluidics Enzymatic-Reactors for Peptide Mapping: Design, Characterization, and PerformanceJournal of Proteome Research, 2004
- Creation of an On-Chip Enzyme Reactor by Encapsulating Trypsin in Sol−Gel on a Plastic MicrochipAnalytical Chemistry, 2003
- Thermal Denaturation: A Useful Technique in Peptide Mass MappingAnalytical Chemistry, 2000
- Online Microreactors/Capillary Electrophoresis/Mass Spectrometry for the Analysis of Proteins and PeptidesAnalytical Chemistry, 1995