A Protocol to Characterize pH Sensing Materials and Systems
- 2 September 2018
- journal article
- research article
- Published by Wiley in Small Methods
- Vol. 3 (2)
Abstract
Although significant progress is made in identifying pH sensing materials and device configurations, a standard protocol for benchmarking performance of next‐generation pH devices is still lacking. In particular, key properties of characterization systems, such as inherent component contributions, time plots for extended‐gate field‐effect transistor (EGFET) measurements, and the input resistance (Rin), often go unreported in studies of pH sensing systems. These properties strongly influence the characterization system and can lead to mistaken attribution of properties to the device. In this paper, a series of essential characterization tests and parameters are reported to evaluate pH systems, such as the zinc oxide EGFET, in a standardized protocol. This EGFET ZnO sensor has a sensitivity of −58.1 mV pH−1, drift range from 2.5 to 14.2 µA h−1, and response time of 136 s. By using a ZnO sensing electrode, it is demonstrated that i) intrinsic contributions of reference electrode and commercial transistor (for EGFET) are not negligible; ii) time plots for EGFET configuration and defining a critical point at the onset of drift are essential for accurate sensitivity, response time, and drift reporting; and iii) the results of the pH sensing system are strongly dependent on the input resistance of the used characterization instruments.Keywords
Funding Information
- National Science Foundation (1541959)
This publication has 76 references indexed in Scilit:
- Iridium oxide pH sensor for biomedical applications. Case urea–urease in real urine samplesBiosensors and Bioelectronics, 2013
- The centenary of glass electrode: from Max Cremer to F. G. K. BauckeJournal of Solid State Electrochemistry, 2010
- Microfabricated Reference Electrodes and their Biosensing ApplicationsSensors, 2010
- Miniaturized pH Sensors Based on Zinc Oxide Nanotubes/NanorodsSensors, 2009
- Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and OutlookSensors, 2009
- Solid-state reference electrodes for potentiometric sensorsJournal of Solid State Electrochemistry, 2008
- Development of low-cost metal oxide pH electrodes based on the polymeric precursor methodAnalytica Chimica Acta, 2008
- State Key Laboratory of Nonlinear Mechanics (LNM), Institute of Mechanics, Chinese Academy of Sciences, Beijing 100080, ChinaSensors, 2007
- Preparation and study on the drift and hysteresis properties of the tin oxide gate ISFET by the sol–gel methodSensors and Actuators B: Chemical, 2002
- Definition of pH scales, standard reference values, measurement of pH and related terminology (Recommendations 1984)Pure and Applied Chemistry, 1985