Non-anatomical placement adversely affects the functional performance of the meniscal implant: a finite element study
- 4 March 2021
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 20 (3) , 1167-1185
Abstract
Non-anatomical placement may occur during the surgical implantation of the meniscal implant, and its influence on the resulting biomechanics of the knee joint has not been systematically studied. The purpose of this study was to evaluate the biomechanical effects of non-anatomical placement of the meniscal implant on the knee joint during a complete walking cycle. Three-dimensional finite element (FE) analyses of the knee joint were performed, based on the model developed from magnetic resonance images and the loading conditions derived from the gait pattern of a healthy male subject, for the following physiological conditions: (i) knee joint with intact native meniscus, (ii) medial meniscectomized knee joint, (iii) knee joint with anatomically placed meniscal implant, and (iv) knee joint with the meniscal implant placed in four different in vitro determined non-anatomical locations. While the native menisci were modeled using the nonlinear hyperelastic Holzapfel–Gasser–Ogden (HGO) constitutive model, the meniscal implant was modeled using the isotropic hyperelastic neo-Hookean model. Placement of the meniscal implant in the non-anatomical lateral-posterior and lateral-anterior locations significantly increased the peak contact pressure in the medial compartment. Placement of the meniscal implant in non-anatomical locations significantly altered the tibial rotational kinematics and increased the total force acting at the meniscal horns. Results suggest that placement of the meniscal implant in non-anatomical locations may restrain its ability to be chondroprotective and may initiate or accelerate cartilage degeneration. In conclusion, clinicians should endeavor to place the implant as closest as possible to the anatomical location to restore the normal knee biomechanics.Keywords
Funding Information
- Singapore University of Technology and Design (2015-2020 President's Doctoral Research Fellowship)
This publication has 82 references indexed in Scilit:
- Effects of Unloading on Knee Articular Cartilage T1rho and T2 Magnetic Resonance Imaging Relaxation Times: A Case SeriesJournal of Orthopaedic & Sports Physical Therapy, 2012
- Association of MR relaxation and cartilage deformation in knee osteoarthritisJournal of Orthopaedic Research, 2011
- Hyperelastic properties of human meniscal attachmentsJournal of Biomechanics, 2011
- The structural properties of the lateral retinaculum and capsular complex of the kneeJournal of Biomechanics, 2009
- Tibiofemoral kinematics and condylar motion during the stance phase of gaitJournal of Biomechanics, 2009
- Gait Mechanics Influence Healthy Cartilage Morphology and Osteoarthritis of the KneeJournal of Bone and Joint Surgery, 2009
- Fatigue failure in the cement mantle of a simplified acetabular replacement modelInternational Journal of Fatigue, 2007
- Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapiesArthritis Research & Therapy, 2007
- Hyperelastic modelling of arterial layers with distributed collagen fibre orientationsJournal of The Royal Society Interface, 2005
- Measurement of lower extremity kinematics during level walkingJournal of Orthopaedic Research, 1990