Clinical Experience With the First Commercially Available Intraoperative Optical Coherence Tomography System
Authors:
- Maximilian PfauMPMaximilian Pfau
- Stephan MichelsSMStephan Michels
- Susanne BinderSBSusanne Binder
- Matthias D. BeckerMBMatthias D. Becker
- 1 November 2015
- journal article
- research article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 46 (10) , 1001-1008
Abstract
BACKGROUND AND OBJECTIVE: A retrospective, single-center case-series was initiated to evaluate initial clinical experience with the first commercially available intraoperative optical coherence tomography system (iOCT). PATIENTS AND METHODS: The Rescan 700 iOCT (Zeiss, Oberkochen, Germany), a spectral-domain OCT system integrated into a surgical microscope, was used in 40 consecutive cases. A standardized review was used to assess whether iOCT imaging resulted in additional information and/or altered decision-making. RESULTS: The iOCT system was usable in conjunction with common chromovitrectomy dyes and tamponades. The surgeons reported that iOCT imaging provided additional information in 74.1% of the posterior and combined surgical cases, which resulted in altered decision-making in 41.9% of the cases. The iOCT imaging time, on average, amounted to 167 seconds. In anterior procedures, the surgeons reported gaining additional information in 22.2% of all cases, but no cases of altered decision-making were reported. Hereby, the iOCT imaging time amounted to 117 seconds, on average. CONCLUSION: The demonstrated results suggest iOCT has the potential to improve the quality of posterior and anterior segment surgery. [ Ophthalmic Surg Lasers Imaging Retina . 2015;46:1001–1008.]Keywords
This publication has 23 references indexed in Scilit:
- The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg With Optical CoherEncE TomogRaphy (PIONEER) Study: 2-Year ResultsAmerican Journal of Ophthalmology, 2014
- Analysis of Pars Plana Vitrectomy for Optic Pit–Related Maculopathy With Intraoperative Optical Coherence TomographyArchives of Ophthalmology (1950), 2011
- FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHYRetina, 2011
- Intraoperative OCT of a Full-Thickness Macular Hole Before and After Internal Limiting Membrane PeelingOphthalmic Surgery, Lasers and Imaging Retina, 2010
- Insights into Advanced Retinopathy of Prematurity Using Handheld Spectral Domain Optical Coherence Tomography ImagingOphthalmology, 2009
- INTRAOPERATIVE USE OF HANDHELD SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING IN MACULAR SURGERYRetina, 2009
- Dry Eye After Cataract Surgery and Associated Intraoperative Risk FactorsKorean Journal of Ophthalmology, 2009
- Intraoperative 2-Dimensional Optical Coherence Tomography as a New Tool for Anterior Segment SurgeryArchives of Ophthalmology (1950), 2005
- Ultrahigh-resolution ophthalmic optical coherence tomographyNature Medicine, 2001
- Optical Coherence TomographyScience, 1991