Preterm Glycosuria – New Data from a Continuous Glucose Monitoring System
Authors:
- Mateusz JagłaMJMateusz Jagła
- Izabela SzymońskaISIzabela Szymońska
- Katarzyna StarzecKSKatarzyna Starzec
- Przemko KwintaPKPrzemko Kwinta
- 2 May 2018
- journal article
- research article
- Published by S. Karger AG in Neonatology
- Vol. 114 (1) , 87-92
Abstract
Background: Careful control of glucose homeostasis is essential for infants with very low birth weight (VLBW). In clinical practice, blood and urine glucose levels are monitored; however, their correlation has not been fully investigated in VLBW infants. Objectives: To evaluate the correlation between interstitial fluid glucose concentration (ISFG), glycosuria, and urine output among VLBW infants through continuous glucose monitoring (CGM). Methods: A prospective, single-center, open cohort study enrolled 74 VLBW infants with a mean birth weight of 1,066 g. CGM (Guardian Real-Time CGM®; Medtronic, Northridge, CA, USA) was used to measure glucose. The urine output was calculated using 4-hour intervals. Reagent strips were used for semiquantitative measurement of glycosuria. Results: The CGM delivered 102,334 glucose measurements. 2,684 urine samples were checked for glycosuria, of which 92.06% remained negative. Corresponding glycemia in samples without glycosuria remained normoglycemic (median 103 mg/dL; 10–90th percentile 80–144 mg/dL). The median glucose concentrations for samples in ascending glycosuria categories 1+, 2+, 3+, and 4+ were 152, 181, 214, and 222 mg/dL, respectively. A moderate correlation between ISFG and urine output was found for categories ≥1+ (rs = 0.56; 95% confidence interval 0.42–0.68; p < 0.001). The urine output was significantly lower when glycosuria was absent (p < 0.05). Polyuria was observed only in glycosuria 4+ (median urine output 9.9; interquartile range 7.4–12.2 mL/kg/h). Conclusions: The renal glucose threshold in VLBW infants is between 150 and 180 mg/dL. A negative result for glycosuria is a reliable screening test to exclude hyperglycemia. Occurrence of glycosuria ≥1+ is an indication to test blood glucose.Keywords
This publication has 11 references indexed in Scilit:
- Glucosuria as an early marker of late-onset sepsis in preterms: a prospective cohort studyBMC Pediatrics, 2015
- Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care SettingPediatrics & Neonatology, 2014
- Prevalence and Determinants of Hyperglycemia in Very Low Birth Weight Infants: Cohort Analyses of the NIRTURE StudyThe Journal of Pediatrics, 2010
- Continuous Glucose Monitoring in Infants of Very Low Birth WeightNeonatology, 2008
- Early Elective Insulin Therapy Can Reduce Hyperglycemia and Increase Insulin-Like Growth Factor-I Levels in Very Low Birth Weight InfantsThe Journal of Pediatrics, 2007
- Hyperglycemia and morbidity and mortality in extremely low birth weight infantsJournal of Perinatology, 2006
- Hyperglycaemia and the very preterm babySeminars in Fetal and Neonatal Medicine, 2005
- The continuous glucose monitoring sensor in neonatal intensive careArchives of Disease in Childhood - Fetal and Neonatal Edition, 2005
- Renal function in sick very low birthweight infants: 4. Glucose excretion.Archives of Disease in Childhood, 1992
- Urinary constituents of the newborn infantThe Journal of Pediatrics, 1962