Quantitative ultrasonic tissue characterization with real-time integrated backscatter imaging in normal human subjects and in patients with dilated cardiomyopathy.
Authors:
- 1 November 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 76 (5) , 1067-1073
Abstract
We have shown previously that the physical properties of myocardium in dogs can be characterized with quantitative ultrasonic integrated backscatter and that interrogation of the tissue with ultrasound can delineate cardiac cycle-dependent changes in ultrasonic backscatter in normal tissue that disappear with ischemia and reappear with reperfusion if functional integrity is restorable. To determine whether this approach can be applied to man, we implemented an automatic gain compensation and continuous data acquisition system to characterize myocardium with quantitative ultrasonic backscatter and to detect cardiac cycle-dependent changes in real time. We developed a two-dimensional echocardiographic system with quantitative integrated backscatter imaging capabilities for use in human subjects that can automatically differentiate ultrasonic signals from blood as opposed to those obtained from tissue and adjust the slope of the gain compensation appropriately. Real-time images were formed from a continuous signal proportional to the logarithm of the integrated backscatter along each A-line. In our initial investigation, 15 normal volunteers (ages 17 to 40 years, heart rates 44 to 88 beats/min) and five patients with dilated cardiomyopathy (ages 22 to 52, heart rates 82 to 120 beats/min) were studied with conventional parasternal long-axis echocardiographic views. Diastolic-to-systolic variation of integrated backscatter in the interventricular septum and left ventricular posterior wall was seen in each of the normal subjects averaging 4.6 +/- 1.4 dB (SD) and 5.3 +/- 1.5 dB (n = 127 sites), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 22 references indexed in Scilit:
- Real-time two-dimensional imaging based on quantitative integrated backscatter L.J. Thomas, III, Benico Barzilai, Samuel A. Wickline, Carl J. Gessler, Burton E. Sobel, Julio E. Perez, and James G. Miller, Department of Physics and Division of Cardiology, Washington University, St. Louis, MO 63130Ultrasonic Imaging, 1986
- Anisotropy of ultrasonic backscatter in canine myocardium: Results in vivo Eric I. Madaras, Julio E. Perez, Burton E. Sobel, and J.G. Miller, Department of Physics and Division of Cardiology, Washington University, St. Louis, MO 63130Ultrasonic Imaging, 1986
- Anisotropy of ultrasonic backscatter in canine myocardium: Theory and results in vitro Jack G. Mottley and J.G. Miller, Department of Physics and Biomedical Computer Laboratory, Washington University, St. Louis, MO 63130Ultrasonic Imaging, 1986
- Ultrasonic characterization of myocardiumProgress in Cardiovascular Diseases, 1985
- The dependence of myocardial ultrasonic integrated backscatter on contractile performance.Circulation, 1985
- Regional differences in the cyclic variation of myocardial backscatter that parallel regional differences in contractile performanceThe Journal of the Acoustical Society of America, 1984
- Applicability of ultrasonic tissue characterization for longitudinal assessment and differentiation of calcification and fibrosis in cardiomyopathyJACC, 1984
- Clinical application of amplitude processing of echocardiographic images.Heart, 1981
- Detection of cardiomyopathic changes induced by doxorubicin based on quantitative analysis of ultrasonic backscatterThe American Journal of Cardiology, 1981
- Ultrasono-cardiotomographic evaluation of histological changes in myocardial infraction.Japanese Heart Journal, 1981