Maximizing Protection by Minimizing Arcing Times in Medium-Voltage Systems
Authors:
- 29 April 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 49 (4) , 1920-1927
Abstract
Arcing faults in the forest product industries are real risks that often lead to severe injuries and fires. From an economic point of view, the consequences due to direct and indirect costs can be extremely high as well. There are various opportunities to prevent arcing faults, but faults cannot be totally eliminated. This is why several approaches to mitigate the consequences of arcing faults have been introduced, particularly in the last decade. Several manufacturers have started to produce arc-flash protection relays based on optical detection of light energy from an arc event. In most applications, the light information is confirmed by overcurrent information before a trip command is initiated to an upstream current-breaking device. The tripping of a circuit breaker, for instance, occurs in only a few milliseconds. In most cases, this seems to be the state-of-the-art technology leading to very reasonable incident energy levels. However, it is essential to be able to minimize not only the thermal impact but also the pressure wave. This paper investigates technology aimed at maximizing the protection for the pressure wave.Keywords
This publication has 11 references indexed in Scilit:
- How accurate are your arc flash hazard study results2010
- Arcing faults in electrical equipment2009
- Testing and Certification of Medium Voltage Control Centers to Arc Resistant Standards2006
- Design Aspects of Industrial Distribution Systems to Limit Arc Flash HazardIEEE Transactions on Industry Applications, 2005
- Selection, application and interchangeability of medium voltage power fuses in motor control centers2005
- IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faultsIEEE Transactions on Energy Conversion, 2003
- Staged tests increase awareness of arc-flash hazards in electrical equipmentIEEE Transactions on Industry Applications, 2000
- The use of low-voltage current-limiting fuses to reduce arc-flash energyIEEE Transactions on Industry Applications, 2000
- ANALYTICAL SOLUTION OF THE TRANSIENTS IN INDUCTION MOTORS DUE TO ASYMMETRICAL TERMINAL FAULTElectric Machines & Power Systems, 1991
- Shaft torques during out-of-phase synchronizationIEEE Transactions on Power Apparatus and Systems, 1977