The Effect of Valsalva Maneuver on P Wave in 12-Lead Surface Electrocardiography in Patients with Paroxysmal Atrial Fibrillation
Authors:
- Kurtuluş ÖzdemirKÖKurtuluş Özdemir
- Hasan GökHGHasan Gök
- Mehmet YaziciMYMehmet Yazici
- Abdullah IçliAIAbdullah Içli
- 1 July 2002
- journal article
- research article
- Published by SAGE Publications in Angiology
- Vol. 53 (4) , 443-449
Abstract
The previous studies relating to the effect of the Valsalva maneuver on P wave do not provide detailed information. In those studies, the parameters related to P wave duration during the release phase of the Valsalva maneuver were evaluated. The authors evaluated P wave amplitude as well as P wave duration during the strain phase of the Valsalva maneuver. Thirty- seven normal subjects and 36 patients with paroxysmal atrial fibrillation (PAF) were included in the study. Twelve-lead surface electrocardiography (ECG) was obtained from all the patients before and during the strain phase of the Valsalva maneuver. The authors evaluated the para meters related to both P wave duration and P wave amplitude. The highest P wave voltage was expressed as the P wave amplitude maximum (P amp max), the lowest P wave voltage as the P wave amplitude minimum (P amp min), and the P wave amplitude dispersion (P amp dispersion) as "the P amp max — the P amp min." Also, the maximum P wave duration was expressed as the P maximum (P max), the minimum P wave duration as the P minimum (P min), and the P wave dispersion as "the maximum P wave duration (P max) — the minimum P wave duration (P min)." All these parameters were measured before and during the strain phase of the Valsalva maneuver. P max, P dispersion, P amp max, and P amp dispersion were higher in patients with PAF compared to those of normal subjects before the Valsalva maneuver. In normal subjects, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly higher in the strain phase of the Valsalva maneuver than before (p<0.01, p < 0.0 1, p<0.05, and p<0.05, respectively). In the patients with PAF, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly lower during the strain phase of the Valsalva maneuver than before. In conclusion, in the patients with PAF, P wave parameters were decreased during the strain phase of the Valsalva maneuver, approaching to the normal levels.Keywords
This publication has 23 references indexed in Scilit:
- Effect of Valsalva maneuver on surface electrocardiographic P-wave dispersion in paroxysmal atrial fibrillationThe American Journal of Cardiology, 2000
- Use of P-wave-triggered, P-wave signal-averaged electrocardiogram to predict atrial fibrillation after coronary artery bypass surgeryAmerican Heart Journal, 1995
- Relationship Between Atrial Conduction Defects and Fractionated Atrial Endocardial Electrograms in Patients with Sick Sinus SyndromePacing and Clinical Electrophysiology, 1993
- Predictive Value of the P Wave at Implantation for Atrial Fibrillation After VVI Pacemaker ImplantationPacing and Clinical Electrophysiology, 1992
- Quantitative analysis of signal-averaged P waves in idiopathic paroxysmal atrial fibrillationThe American Journal of Cardiology, 1991
- Electrocardiographic features of P waves from patients with transient atrial fibrillation.Japanese Heart Journal, 1988
- Left atrial enlargement. Echocardiographic assessment of electrocardiographic criteria.Circulation, 1976
- P-Wave Analysis in Valvular Heart DiseaseCirculation, 1964
- ABNORMAL P WAVES AND PAROXYSMAL TACHYCARDIAHeart, 1963
- Effects of Valsalva's Man uvre on the Normal and Failing CirculationBMJ, 1955