Abstract
In this study the feasibility of a time‐resolved, three‐dimensional (3D), three‐directional flow‐sensitive balanced steady‐state free precession (bSSFP) sequence is demonstrated. Due to its high signal‐to‐noise ratio (SNR) in blood and cerebrospinal fluid (CSF) this type of sequence is particularly effective for acquisition of blood and CSF flow velocities. Flow sensitivity was achieved with the phase‐contrast (PC) technique, implementing a custom algorithm for calculation of optimal gradient parameters. Techniques to avoid the most important sources of bSSFP‐related artifacts (including distortion due to eddy currents and signal voids due to flow‐related steady‐state disruption) are also presented. The technique was validated by means of a custom flow phantom, and in vivo experiments on blood and CSF were performed to demonstrate the suitability of this sequence for human studies. Accurate depiction of blood flow in the cerebral veins and of CSF flow in the cervical portion of the neck was obtained. Possible applications of this technique might include the study of CSF flow patterns, direct in vivo study of pathologies such as hydrocephalus and Chiari malformation, and validation for the existing CSF circulation model. Magn Reson Med, 2009.Keywords
Funding Information
- Swiss National Science Foundation (320000-113492/1, 325200-118377)
This publication has 26 references indexed in Scilit:
- In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 TNeuroradiology, 2008
- Time‐resolved 3D MR velocity mapping at 3T: Improved navigator‐gated assessment of vascular anatomy and blood flowJournal of Magnetic Resonance Imaging, 2007
- Visualization of hemodynamics in intracranial arteries using time‐resolved three‐dimensional phase‐contrast MRIJournal of Magnetic Resonance Imaging, 2007
- Improved cerebrospinal fluid flow measurements using phase contrast balanced steady-state free precessionMagnetic Resonance Imaging, 2007
- Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imagingMagnetic Resonance in Medicine, 2006
- Flow compensation in balanced SSFP sequencesMagnetic Resonance in Medicine, 2005
- Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacementThe Journal of Thoracic and Cardiovascular Surgery, 2005
- Analysis and compensation of eddy currents in balanced SSFPMagnetic Resonance in Medicine, 2005
- Balanced phase‐contrast steady‐state free precession (PC‐SSFP): A novel technique for velocity encoding by gradient inversionMagnetic Resonance in Medicine, 2003
- Detection of sea-water motion by nuclear precessionJournal of Geophysical Research, 1960