Study on the Measurement of the On-Site Overvoltage and Internal Temperature Rise Simulation of the EMU Arrester
Open Access
- 8 August 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7925
Abstract
In order to analyze the explosion accidents of the CRH5 EMU roof arrester in recent years, an internal temperature measuring platform based on fluorescence fiber was established, and the temperature distribution characteristics under the continuous operating voltage and high-current impulse were analyzed. The test results show that passing section overvoltage and steep impulse overvoltage have higher amplitudes, while high-harmonic overvoltage has a lower amplitude but a longer duration. The maximum temperature rise of the arrester was 5.2 °C under 34 kV for 3 h. The surface temperature of the valve plate column was high in the middle and low on both sides; the maximum temperature difference at different positions was only 2.2 °C. The maximum temperature of the valve plate column rose to 97.6 °C under 105 times of the high-current impulse, and the maximum temperature difference at different positions reached 33.8 °C. Then, the actual overvoltage of the arrester in operation was measured and analyzed statistically, and the arrester simulation model was established. The temperature characteristics of the normal arrester and the arrester with the electric tree were studied under the actual typical overvoltage, and the influence of air velocity on the internal temperature rise was analyzed. The simulation results show that, due to the low amplitude and small current of high-harmonic overvoltage, the internal temperature rise of the normal and defective arresters was very small. Under the effects of passing section overvoltage and steep impulse overvoltage, the internal temperature of the normal arrester can reach 36.57 °C and 241 °C, and the arrester with the electric tree defect can reach 44.75 °C and 536 °C, respectively. The air velocity has little effect on the internal temperature rise of the arrester. Passing section overvoltage and steep impulse overvoltage occur frequently and have an obvious influence on the internal temperature rise of the arrester, so the roof overvoltage of the EMU is an important reason for the arrester burst.Keywords
Funding Information
- Key R&D Project of Hebei Province (19212109D)
- National Key Research and Development Program of China (2018YFF01011903)
This publication has 19 references indexed in Scilit:
- Suppression of Cable Overvoltage in a High-Speed Electric Multiple Units SystemIEEE Transactions on Electromagnetic Compatibility, 2018
- A Network-Based Method for the EMU Train High-Level Maintenance Planning ProblemApplied Sciences, 2017
- Electrical and temperature correlation to monitor fault condition of ZnO surge arrester2017
- Condition monitoring of discharged ZnO surge arrester on temperature distribution under various design conditions2016
- Application of finite element method for electro‐thermal modeling of metal oxide surge arresterComputer Applications in Engineering Education, 2015
- DC Component From Pantograph Arcing in AC Traction System—Influencing Parameters, Impact, and Mitigation TechniquesIEEE Transactions on Electromagnetic Compatibility, 2011
- ZnO varistors with high voltage gradient and low leakage current by doping rare-earth oxideScience China Technological Sciences, 2008
- Line-pantograph EMI in railway systemsIEEE Instrumentation & Measurement Magazine, 2001
- Diagnostics and monitoring of metal-oxide surge arresters in high-voltage networks-comparison of existing and newly developed proceduresIEEE Transactions on Power Delivery, 2001
- Development of high gradient zinc oxide nonlinear resistors and their application to surge arrestersIEEE Transactions on Power Delivery, 1998