A Sensitive Fluorimetric Method for the Determination of Epinephrine
Authors:
- 1 March 2005
- journal article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 15 (2) , 131-136
Abstract
A sensitive fluorimetric method for the determination of epinephrine (E) is described in this paper. The experiments indicate that epinephrine can react with formaldehyde (HCHO) in an acid medium to form a condensation product, which can be oxidized by potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in borax buffer (pH = 9.5). The reaction product can emit strong fluorescence. Ascorbic acid (AA) is used in order to consume excess potassium hexacyanoferrate and stabilize the fluorescent product. Under optimum conditions, a linear relationship has been obtained between the fluorescence intensity and the concentration of epinephrine in the range of 1.4×10−9−2.1×10−6 mol/l, and the detection limit is 2.4×10−10 mol/l (4.3×10−11 g/ml, S/N = 3). The method is applied for the determination of E in both actual sample and the synthetic sample with E and norepinephrine (NE) by using the coupling technique of synchronous fluorimetry and H-point standard addition method, and the results obtained are satisfactory.Keywords
This publication has 11 references indexed in Scilit:
- Flow injection chemiluminescence determination of epinephrine using epinephrine-imprinted polymer as recognition materialAnalytica Chimica Acta, 2003
- Evaluation of a sol–gel derived carbon composite electrode as an amperometric detector for capillary electrophoresisJournal of Chromatography A, 2003
- Post-column terbium complexation and sensitized fluorescence detection for the determination of norepinephrine, epinephrine and dopamine using high-performance liquid chromatographyAnalytica Chimica Acta, 2002
- Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminolAnalytica Chimica Acta, 2001
- Molecular imprinting polymer coated BAW bio-mimic sensor for direct determination of epinephrineAnalytica Chimica Acta, 2000
- Analysis of epinephrine from fifteen different dental anesthetic formulations by capillary electrophoresisJournal of Chromatography A, 1999
- Cyclic voltammetry determination of epinephrine with a carbon fiber ultramicroelectrodeTalanta, 1998
- Fluorimetric determination of epinephrine with o-phenylenediamineAnalytica Chimica Acta, 1998
- Fluorimetric determination of epinephrine with 2,3-diaminonaphthaleneSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 1997
- Flow-injection biamperometric determination of epinephrineJournal of Pharmaceutical and Biomedical Analysis, 1997