Numerical Investigation of the Effects of Prosthetic Aortic Valve Design on Aortic Hemodynamic Characteristics
Open Access
- 19 February 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (4) , 1396
Abstract
The superior performance of single-point attached commissures (SPAC) molded valve design has been validated by several numerical, in vitro and in vivo animal studies. However, the impacts of the SPAC molded valve design on aortic hemodynamic environments are yet to be investigated. In this study, multiscale computational models were prepared by virtually implanting prosthetic aortic valves with SPAC tubular, SPAC molded and conventional designs into a patient-specific aorta, respectively. The impacts of the valve designs on efferent flow distribution, flow pattern and hemodynamic characteristics in the aorta were numerically investigated. The results showed that despite the overall flow phenomena being similar, the SPAC tubular valve exhibited a suboptimal performance in terms of higher spatially averaged wall shear stress (SAWSS) in ascending aorta (AAo), higher helix grade, stronger secondary flow mean secondary velocity in descending aorta, as well as more complex vortex distribution. The results from the current study extend the understanding of hemodynamic impacts of the valve designs, which would further benefit the optimization of the prosthetic aortic valve.Keywords
Funding Information
- National Natural Science Foundation of China (11802227, 11971379)
This publication has 100 references indexed in Scilit:
- Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending AortaCirculation: Cardiovascular Imaging, 2012
- On the Use of In Vivo Measured Flow Rates as Boundary Conditions for Image-Based Hemodynamic Models of the Human Aorta: Implications for Indicators of Abnormal FlowAnnals of Biomedical Engineering, 2011
- Effect of swirling flow on platelet concentration distribution in small-caliber artificial grafts and end-to-end anastomosesActa Mechanica Sinica, 2011
- Simulation of blood flow in human aorta with emphasis on outlet boundary conditionsApplied Mathematical Modelling, 2011
- Blood flow in the rabbit aortic arch and descending thoracic aortaJournal of The Royal Society Interface, 2011
- Mechanistic insight into the physiological relevance of helical blood flow in the human aorta: an in vivo studyBiomechanics and Modeling in Mechanobiology, 2010
- Finite Element Investigation of Stentless Pericardial Aortic Valves: Relevance of Leaflet GeometryAnnals of Biomedical Engineering, 2010
- Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular ProsthesesCardiovascular Engineering and Technology, 2010
- Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRIAnnals of Biomedical Engineering, 2009
- In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance ImagingAnnals of Biomedical Engineering, 2008