Comparison of Laser Ablation and Dried Solution Aerosol as Sampling Systems in Inductively Coupled Plasma Mass Spectrometry
Authors:
- 1 December 2004
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (12) , 1481-1487
Abstract
This paper describes a study designed to determine the possibility of using a dried aerosol solution for calibration in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The relative sensitivities of tested materials mobilized by laser ablation and by aqueous nebulization were established, and the experimentally determined relative sensitivity factors (RSFs) were used in conjunction with aqueous calibration for the analysis of solid steel samples. To such a purpose a set of CRM carbon steel samples (SS-451/1 to SS-460/1) were sampled into an ICP-MS instrument by solution nebulization using a microconcentric nebulizer with membrane desolvating (D-MCN) and by laser ablation (LA). Both systems were applied with the same ICP-MS operating parameters and the analyte signals were compared. The RSF (desolvated aerosol response/ablated solid response) values were close to 1 for the analytes Cr, Ni, Co, V, and W, about 1.3 for Mo, and 1.7 for As, P, and Mn. Complementary tests were carried out using CRM SS-455/1 as a solid standard for one-point calibration, applying LAMTRACE software for data reduction and quantification. The analytical results are in good agreement with the certified values in all cases, showing that the applicability of dried aerosol solutions is a good alternative calibration system for laser ablation sampling.Keywords
This publication has 16 references indexed in Scilit:
- Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MSJournal of Analytical Atomic Spectrometry, 2003
- Spatially-resolved analysis of solids by laser ablation-inductively coupled plasma-mass spectrometry: trace elemental quantification without matrix-matched solid standardsJournal of Analytical Atomic Spectrometry, 2003
- Determination of trace elements in high-purity platinum by laser ablation inductively coupled plasma mass spectrometry using solution calibrationJournal of Analytical Atomic Spectrometry, 2001
- Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1999
- Calibration of Laser Ablation Inductively Coupled Plasma Mass Spectrometry Using Standard Additions with Dried Solution AerosolsAnalytical Chemistry, 1998
- Atomic Spectrometry Update–Atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Toward the Next Generation of Atomic Mass SpectrometersJournal of Analytical Atomic Spectrometry, 1997
- Calibration Studies on Dried Aerosols for Laser Ablation–Inductively Coupled Plasma Mass SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- Universal Calibration Strategy for Laser Ablation Inductively Coupled Plasma Mass Spectrometry Based on the Use of Aqueous Standards With Modified Absorption CoefficientsAnalytical Communications, 1997
- Calibration studies in laser ablation microprobe-inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1989